Old 01-04-2007, 02:43 PM   #1 (permalink)
wmarwells
Junior Member

Activity Longevity
0/20 7/20
Today Posts
0/0 ssssssss4
Rep Power: 0wmarwells is an unknown quantity at this point
Country:
Cool Technical Problem

I am working on a Vodavi XTS with a PRI choked down to 4 clusters, recently the customer complained of incoming calls having little "blurps" during the conversation. I heard the same thing while on a call, it sounded like the voice was distorted for about a split second. I have contacted the Service provider and requested them to do invasive testing on the circuit. I am not showing any "slip" alarms on the data dump, has anyone encountered this? What was the resoulution?
wmarwells is offline   sendpm.gif Reply With Quote
Old 01-05-2007, 04:57 PM   #2 (permalink)
Ramjet
Senior Member
 
Ramjet's Avatar
Ramjet is wore ass out from the holidays!

Activity Longevity
10/20 20/20
Today Posts
0/0 sssss1425
Rep Power: 8Ramjet is on a distinguished road
Gender:
Country:
I almost hate to ask, what do you mean when you say choked down to 4 clusters. I don't have any XTS running PRI, but I do have an STSe running it.
__________________
Two snips, a snort, a turn, a fly, and a grunt, and it was so simple, like the jitterbug, it plum evaded me!
Ramjet is offline   sendpm.gif Reply With Quote
Old 01-27-2007, 10:17 PM   #3 (permalink)
wmarwells
Junior Member

Activity Longevity
0/20 7/20
Today Posts
0/0 ssssssss4
Rep Power: 0wmarwells is an unknown quantity at this point
Country:
In flash 24 programming when you assign a card to a specific slot, the code for a full PRI is 08. If you are getting less than a full PRI from the carrier, you have to program the slot for the number of channels closest to what the carrier is providing, according to Vodavi each cluster consists of 4 channels. (example: I am getting 9 channels on a PRI from the provider, I would enter the code of 083 in flash programming indicating I am making the PRI 12 channels. I would then put channels 10-12 in line group 0 making them unaccessable when the TGA number is dialed which in most cases is the number 9.) I hope I didn't go overboard on the explanation.
wmarwells is offline   sendpm.gif Reply With Quote
Old 01-29-2007, 08:46 AM   #4 (permalink)
Ramjet
Senior Member
 
Ramjet's Avatar
Ramjet is wore ass out from the holidays!

Activity Longevity
10/20 20/20
Today Posts
0/0 sssss1425
Rep Power: 8Ramjet is on a distinguished road
Gender:
Country:
Not at all, but what about the trouble you were having?
__________________
Two snips, a snort, a turn, a fly, and a grunt, and it was so simple, like the jitterbug, it plum evaded me!
Ramjet is offline   sendpm.gif Reply With Quote
Old 01-30-2007, 09:12 AM   #5 (permalink)
Phonecop
Junior Member
 
Phonecop's Avatar
Phonecop has no status.

Activity Longevity
0/20 8/20
Today Posts
0/0 ssssssss7
Location: Michigan
Rep Power: 0Phonecop is an unknown quantity at this point
Gender:
Country:
re: PRI

This may be getting back to basics, but make sure your clock switch is in the proper position (ie, if this is the only pipe, you should look for timing from this circuit, and not the KSU clock). If you have multiple pipes, such as a combination of T1s, and PRIs, the clock switches and cables are very important...Otherwise they will fight for control.



Hope this helps, Randy.
Phonecop is offline   sendpm.gif Reply With Quote
Old 02-02-2007, 12:32 AM   #6 (permalink)
wmarwells
Junior Member

Activity Longevity
0/20 7/20
Today Posts
0/0 ssssssss4
Rep Power: 0wmarwells is an unknown quantity at this point
Country:
I have verified the clocking, I'm not showing any slips, the system has been installed for over a year and the problem just started about a month ago. The carrier shows the circuits to be clean and will not consent to intrusive testing. The carrier did say they were showing "line code violations" that were coming from the switch that may be caused by a connection issue but the wires are secure.
wmarwells is offline   sendpm.gif Reply With Quote
Old 02-02-2007, 09:59 AM   #7 (permalink)
Phonecop
Junior Member
 
Phonecop's Avatar
Phonecop has no status.

Activity Longevity
0/20 8/20
Today Posts
0/0 ssssssss7
Location: Michigan
Rep Power: 0Phonecop is an unknown quantity at this point
Gender:
Country:
If it has a history of running clean, I would first try the CSU/TSU that is between the PRI and the Smart jack. If no help, I would next try the PRI card. Also, don't remove telco from the equation...the response they gave you sounds "canned". If the first two steps don't help, you've done your dilligence, and it would be appropriate to press the carrier to make the next move, such as the smart jack or a pair change.



Good luck, Randy.
Phonecop is offline   sendpm.gif Reply With Quote
Old 02-28-2007, 04:28 PM   #8 (permalink)
wmarwells
Junior Member

Activity Longevity
0/20 7/20
Today Posts
0/0 ssssssss4
Rep Power: 0wmarwells is an unknown quantity at this point
Country:
Sorry for the delay in communicating the problem resolution, To make a long story short, the "Carrier" did not have QOS turned on in the router to give voice packets priority over data packets. Once they handled this, I haven't heard from the customer any more.
wmarwells is offline   sendpm.gif Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
A few of technical questions Mr_Pmzrq Altigen 2 08-18-2006 01:20 PM
Technical info about NT5K83 JEHartmann Meridian Systems 6 05-31-2006 09:15 AM
New Nortel Networks Technical Support Portal Launch Fletch Meridian Systems 4 08-01-2004 10:37 AM
Communication Technical Refernces Dtu Technology Chat 1 03-28-2004 08:28 PM
Technical/Maint. question regarding TTY Rachelle Meridian Systems 6 06-30-2003 10:37 PM


All times are GMT -5. The time now is 03:14 AM.

Tags   |   Advertise    |    Media Partners   |    Admin   |   About us   |   Contact Us   |   RSS   

Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.0.0
Copyright PBXINFO LLC 2006