Rep Power: 0 ![]() | rolm 8000 limiting an extension I have seen there is an option so an extension can only do local calls. Is there a way to limit an extension to just three digits there by limiting it to only being able to call within the switch and not outside of the switch? | ||||||||
| | |
| | #3 (permalink) | |||||||||
| Junior Member ![]()
Rep Power: 0 ![]() | Quote:
Then set COSx to phone. I use the following: 0- inhouse only (NO trkgrp access at all; note 911 WILL go out; fed law) 1- 2- dial local only (NO long distance) 3- 4- DID inbound 5- 6- 7- Phonemail extns only 8- ROLMNet (if used) access only (COS 8 to dial 8 ) 9- ROLMnet and local calls (if no ROLMnet, can be used for local only) 10- Normal user; long distance and ROLMNet 11- ACD user 12- ACD Supv 13- spare 14- Executive (for possible personal trunk access) 15- telecom and ATC only (FULL access including Direct Trunk Select, etc) 8000/9000/9751/9006/9200/Phonemail certified | |||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| ROLM 8000 extension display name | fred1965 | Siemens / Rolm | 10 | 10-01-2008 09:09 AM |
| ROLM 8000 Fwd extension to Trunk | micky | Siemens / Rolm | 4 | 07-22-2008 08:04 PM |
| rolm 8000 | bstk64 | Siemens / Rolm | 4 | 07-22-2008 07:53 PM |
| Rolm 8000 camping | fred1965 | Asterisk Systems | 1 | 07-22-2008 07:45 PM |
| ROLM 8000: delete a dumby extension | fred1965 | Siemens / Rolm | 2 | 04-30-2008 07:30 AM |