Old 04-14-2006, 07:02 AM   #1 (permalink)
happs
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss11
Rep Power: 0happs is an unknown quantity at this point

Total Points:
Donate
Country:

ROLM 9751 CBX Shelf Not Working

Dear Forum Members!

We are having trouble with a ROLM 9751 CBX, the problem is that one of its shelves are not working (SHELF No 7), the CBX has 8 shelves in total

All the Rolm Link INterface Cards , Mother Board Power Card and all other cards installed on this shelf have been tested and all are working fine, the phones connected to this shelf are getting power but there is no dial tone

Now could someone please assist us on how to troubleshoot this problem?
What could possible be wrong?

Any help would be highly appreciated

Regards

happs
happs is offline   sendpm.gif Reply With Quote
Old 04-14-2006, 10:50 AM   #2 (permalink)
PP
Senior Member
 
PP's Avatar

Activity Longevity
9/20 20/20
Today Posts
0/0 sssss1560
Location: MIAMI, FLA
Rep Power: 7PP will become famous soon enough

Total Points:
Donate

Maybe A Stupid Question, But Did You Place Them In The Map. If So What Kind Of Errors Are You Getting
PP is offline   sendpm.gif Reply With Quote
Old 04-15-2006, 12:23 AM   #3 (permalink)
happs
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss11
Rep Power: 0happs is an unknown quantity at this point

Total Points:
Donate
Country:

Clarification

PP, thanks for your reply....yes this shelf (no 7) was working till a few days ago, we lost power some days back and when the power was restored this shelf stopped working

ive tried connecting phones to this shelf (via the rolm interface card) and the phones and everything is getting appropriate power...so what else could go wrong....

also with reference to the second thread, what exactly is the command to activate these cards in say shelf 8, im not good with this stuff..sorry for any inconvenience

Once again thanks in advance for your help
happs is offline   sendpm.gif Reply With Quote
Old 04-15-2006, 04:56 PM   #4 (permalink)
PP
Senior Member
 
PP's Avatar

Activity Longevity
9/20 20/20
Today Posts
0/0 sssss1560
Location: MIAMI, FLA
Rep Power: 7PP will become famous soon enough

Total Points:
Donate

Do List Down And See If There Is Anything Down On Shelf 8, If So Go Into Diagnostics By Typing Dia. Then Type Up And The Pad Address, Like Up Pad 0816. You Still Didn't Say If You Had Anything The Error Table, Do A Li Errh ;;; And Post It
PP is offline   sendpm.gif Reply With Quote
Old 04-15-2006, 04:59 PM   #5 (permalink)
PP
Senior Member
 
PP's Avatar

Activity Longevity
9/20 20/20
Today Posts
0/0 sssss1560
Location: MIAMI, FLA
Rep Power: 7PP will become famous soon enough

Total Points:
Donate

Should Look Like This
% Li Errh ;;;

Target Source System Id Release Bind Date Current Date/time
1 1 Metro40510 9005.6.84 27/jan/98 4/15/2006 17:56:39
----------------------------------------------------------------------


Telephony Problem Overview
--------------------------
Last Completely Cleared 07:48:48 Mar-22-2005

T1 01/010714 Interm Pri = 136 (major) 1st = 13:36 03/29
T1 01/030709 Failed Pri = 248 (warn ) 1st = 02:01 03/24
T1 01/030714 Passed Pri = 252 1st = 04:32 04/08
T1 01/030701 Failed Pri = 252 1st = 00:32 04/06
T1 01/030714 Passed Pri = 252 1st = 00:26 04/06
T1 01/030714 Failed Pri = 252 1st = 22:04 04/05
T1 01/010714 Interm Pri = 252 1st = 13:36 03/29
T1 01/010701 Passed Pri = 252 1st = 13:36 03/29
PP is offline   sendpm.gif Reply With Quote
Old 04-27-2006, 04:49 AM   #6 (permalink)
happs
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss11
Rep Power: 0happs is an unknown quantity at this point

Total Points:
Donate
Country:

li errh;;; output

hello sorry for the delay

ive finally managed to get the output required earlier

% Li Errh ;;;








ECC PARITY ERRORS


---------------------------------------------------------------------






TYPE BIT ADDRESS SLOT


SINGLE #9 #27B3FD #A


SINGLE #9 #27B3F9 #A


SINGLE #9 #27B3ED #A







and so on...













Telephony Problem Overview


--------------------------







EXP
FAILED PRI=006 (MAJOR) EXP 01/070201 FAILED PRI=027 (MAJOR) EXP 01/070201 FAILED PRI=027 (MAJOR) ISB[*} ISB FAILED PRI=038 (MAJOR) ISB[*} ISB FAILED PRI=039 (MAJOR) ISB[*} ISB FAILED PRI=041 (MAJOR) TASA[*] 01/0201 FAILED PRI=045 (MAJOR) TASA[*] 01/0201 FAILED PRI=046 (MAJOR) TASA[*] 01/0201 FAILED PRI=047 (MAJOR) TASA[*] 01/0201 FAILED PRI=048 (MAJOR) TASA[*] 01/0201 FAILED PRI=048 (MAJOR) TC/TDC[*] CPU 2 SHELF FAILED PRI=056 (MAJOR) EXP[*]
FAILED PRI=059 (MAJOR) LINE
FAILED PRI=150 (MAJOR) CDR
FAILED PRI=150 (MAJOR) ATC 01/060605 PASSED PRI=170 (MAJOR) ATC 01/052101 FAILED PRI=170 (MAJOR) ATC 01/041801 FAILED PRI=170 (MAJOR) SMC 01/1400 FAILED PRI=170 (MAJOR) IOSWLINK CPU/SHELF PASSED PRI=027 (MAJOR) CARD ID 01/0821 FAILED PRI=240 (WARN) CARD ID 01/0818 FAILED PRI=240 (WARN) CARD ID 01/0727 FAILED PRI=240 (WARN) CARD ID 01/0724 FAILED PRI=240 (WARN) CARD ID 01/0724 FAILED PRI=240 (WARN) CARD ID 01/0724 FAILED PRI=240 (WARN) CARD ID 01/0721 FAILED PRI=240 (WARN) CARD ID 01/0626 FAILED PRI=240 (WARN) CARD ID 01/0415 FAILED PRI=240 (WARN) CDR
FAILED PRI=246 (WARN) CONF 01/082801 FAILED PRI=247 (WARN) CONF 01/082807 FAILED PRI=247 (WARN) CONF 01/082803 FAILED PRI=247 (WARN) DTMF 01/060601 PASSED PRI=247 (WARN) TONE 01/0429 INTERIM PRI=247 (WARN) RPV 01/081825 UNPLUG PRI=247 (WARN) RPV 01/081816 UNPLUG PRI=247 (WARN) RPV 01/081539 UNPLUG PRI=247 (WARN) RPV 01/062632 UNPLUG PRI=247 (WARN) RPV 01/062631 UNPLUG PRI=247 (WARN) RPV 01/031533 UNPLUG PRI=247 (WARN) RPV 01/031540 UNPLUG PRI=247 (WARN) RPV 01/031544 UNPLUG PRI=247 (WARN) RPV 01/031566 FAILED PRI=247 (WARN)














LONG OUTPUT







EXPANDER CONNECTION TABLE RAM ERROR






POSSIBLE MISSING EXPANDER SHELF 7






BAD EXPANDER SHELF 7












INTER-SHELF BUS (ISB) DEFECT






SOURCE BUS (ISB) SHORT!!!!












TURNAROUND SA/MB FAILS HARDWARE CONFIG (TASA[*})










ACTIVE STANDBY FRAME SYNC FAILING











BAD EXPANDER ON SHELF: 3 4 5 6 7 8











85 LINE CHANNELS HAVE FAILED IN THE NODE






CHECK ATC / CABLE / REPLACE ATC


thanks for your help in advance
happs is offline   sendpm.gif Reply With Quote
Old 04-27-2006, 05:09 AM   #7 (permalink)
happs
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss11
Rep Power: 0happs is an unknown quantity at this point

Total Points:
Donate
Country:

pdf file attached

sorry for last post...didnt know the forum is going to remove the formatting

please see attached pdffile for the log

thanks
Attached Images
File Type: pdf rolm log.pdf (22.2 KB, 3 views)
happs is offline   sendpm.gif Reply With Quote
Old 04-27-2006, 02:32 PM   #8 (permalink)
PP
Senior Member
 
PP's Avatar

Activity Longevity
9/20 20/20
Today Posts
0/0 sssss1560
Location: MIAMI, FLA
Rep Power: 7PP will become famous soon enough

Total Points:
Donate

You Have A Sick Switch, Shelf 7 Has A Bad Expander On The Active Side That's Why You Have No Shelf 7 And A Bad Tasa On The Standby Side That's Why It Won't Switchover. You Need To Start Clearing The Pri 059 To 006 Errors Or You Will Never Get That Switch Back Up
PP is offline   sendpm.gif Reply With Quote
Old 04-29-2006, 02:03 AM   #9 (permalink)
happs
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss11
Rep Power: 0happs is an unknown quantity at this point

Total Points:
Donate
Country:

thanks

Dear PP

thanks a lot for your reply, really appreciate it

so i need to replace to cards in the CBX if i gather correctly (please correct me if i got this wrong)

i) Rolm Expander card for shelf 7
ii) TASA card which i think is same for the whole CBX

the PRI ranges u mention also show a "SOURCE BUS (ISB) SHORT!!!"

does it mean i need to buy an ISB card as well?

lastly can you please help me with part numbers....where can i locate this products i need to buy..i got some sources to buy rolm cards from the internet..if u know any..please let me know..thanks once again ... : )
happs is offline   sendpm.gif Reply With Quote
Old 04-29-2006, 04:39 PM   #10 (permalink)
PP
Senior Member
 
PP's Avatar

Activity Longevity
9/20 20/20
Today Posts
0/0 sssss1560
Location: MIAMI, FLA
Rep Power: 7PP will become famous soon enough

Total Points:
Donate

No The Isb Error Is Most Likely Caused By The Tasa Or Expander Or Both
PP is offline   sendpm.gif Reply With Quote
Post New Thread  Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Does anyone know when the Rolm 9751 (Release 9006) was born? jtiggett Siemens / Rolm 5 07-16-2007 04:42 PM
change the system time for Rolm 9751 henry senephansiri Siemens / Rolm 1 04-03-2006 08:45 PM
ROLM 9751 problem Malibu406 Siemens / Rolm 1 03-11-2006 09:05 PM

Tags   |   Advertise    |    Media Partners   |    Admin   |   About us   |   Contact Us   |   RSS   


Powered by vBulletin® Version 3.6.4
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.0.0
Copyright PBXINFO LLC 2006