Old July 9th, 2009   #1 (permalink)
Junior Member

Activity Longevity
0/20 2/20
Today Posts
0/0 ssssssss4
Location: Warsaw
Rep Power: 0vogis is a newbie
Gender:
Country:
Outgoing KX-TES824

Hi,

I'm new here. First I want say hello everyone!

I'm student and I'm doing some exercises on KX-TES824. It's quite new in my application and I have problems with some basic functions.

I'm programming it witch PC, using given software. PC is connected to KX-TES824 with USB. Software is working well.

I have plugged in only KX-TG7220PD(JACK 01) as a normal phone, and KX-MB783(JACK 02) as a fax.

External line is plugged into CO 01.

I don't know how set KX-TES824 using pc:
1) to able phone plugged into JACK 01 calling to external numbers
2) when someone is calling from external number, redirecting to the phone on JACK 01
3) when fax is incoming redirecting to FAX plugged into JACK 02.

It will be very nice to recive some advices!
Thank you for your attention!
vogis is offline   sendpm.gif Reply With Quote
Old July 9th, 2009   #2 (permalink)
ps1
Senior Member

Activity Longevity
1/20 2/20
Today Posts
0/0 ssssss105
Rep Power: 0ps1 is a newbie
Gender:
Country:
Quote:
Originally Posted by vogis View Post
Hi,

I'm new here. First I want say hello everyone!

I'm student and I'm doing some exercises on KX-TES824. It's quite new in my application and I have problems with some basic functions.

I'm programming it witch PC, using given software. PC is connected to KX-TES824 with USB. Software is working well.

I have plugged in only KX-TG7220PD(JACK 01) as a normal phone, and KX-MB783(JACK 02) as a fax.

External line is plugged into CO 01.

I don't know how set KX-TES824 using pc:
1) to able phone plugged into JACK 01 calling to external numbers
2) when someone is calling from external number, redirecting to the phone on JACK 01
3) when fax is incoming redirecting to FAX plugged into JACK 02.

It will be very nice to recive some advices!
Thank you for your attention!
Welcome. First of all to dial out you need to prgram the CO lines, in default they are all connected. Since you only have CO1 you need to disable 2-8. In default all the handsets should ring on i/c calls to the co. If you have a fax connected, I know in the UK you will need a disa card, which detects the CNG tones of a fax machine and redirects it to the fax ext. Hope this helps
ps1 is offline   sendpm.gif Reply With Quote
Old July 10th, 2009   #3 (permalink)
Moderator

Activity Longevity
12/20 14/20
Today Posts
0/0 ssssss630
Location: NW Ohio
Rep Power: 6Cnavarro is on a distinguished road
Gender:
Country:
Quote:
Originally Posted by vogis View Post
Hi,



I don't know how set KX-TES824 using pc:
1) to able phone plugged into JACK 01 calling to external numbers
2) when someone is calling from external number, redirecting to the phone on JACK 01
3) when fax is incoming redirecting to FAX plugged into JACK 02.

It will be very nice to recive some advices!
Thank you for your attention!
First advice is fix your country of origin.

Ringing is programmed in the section marked 3.CO In our systems, the DISA trunk is also assigned in the same place. We can assign the FAX extension (put it at 106 for uniformity btw) and program the CNG to ring that extension under DISA.

Carl
Cnavarro is offline   sendpm.gif Reply With Quote
Old July 10th, 2009   #4 (permalink)
Junior Member

Activity Longevity
0/20 2/20
Today Posts
0/0 ssssssss4
Location: Warsaw
Rep Power: 0vogis is a newbie
Gender:
Country:
Thank you very much for so helpful advices!
1) and 2) are working well. Tomorow I'll test the fax. I think i have a DISA card inside

What can I do to make faster, calling from telephone (plugged into JACK01) to the external number? In this moment, the connection dure very long... (about 10s)
Should I always put 9 before the external number? Is it possible to to set telephone on JACK01, always calling outside numbers?
vogis is offline   sendpm.gif Reply With Quote
Old July 10th, 2009   #5 (permalink)
Senior Member
 
KMETECH's Avatar
KMETECH has no status.

Activity Longevity
0/20 8/20
Today Posts
0/0 ssssss145
Rep Power: 0KMETECH is a newbie
Country:
Quote:
Originally Posted by vogis View Post
Thank you very much for so helpful advices!
1) and 2) are working well. Tomorow I'll test the fax. I think i have a DISA card inside

What can I do to make faster, calling from telephone (plugged into JACK01) to the external number? In this moment, the connection dure very long... (about 10s)
Should I always put 9 before the external number? Is it possible to to set telephone on JACK01, always calling outside numbers?
yes it is possible idle line preference!
KMETECH is offline   sendpm.gif Reply With Quote
Old July 10th, 2009   #6 (permalink)
Senior Member

Activity Longevity
7/20 10/20
Today Posts
0/0 ssssss273
Location: Dublin
Rep Power: 4rivet is on a distinguished road
Gender:
Country:
also make sure system is set to DTMF not pulse on all lines

peter
rivet is offline   sendpm.gif Reply With Quote
Old July 11th, 2009   #7 (permalink)
Junior Member

Activity Longevity
0/20 2/20
Today Posts
0/0 ssssssss4
Location: Warsaw
Rep Power: 0vogis is a newbie
Gender:
Country:
Thank you very much! It's working well, but I can't find "idle line preference"...

Where I can find "idle line preference" in "Maintenance Console"?

Now, next question: how record OGM "Welcome in ... Please press "1" to talk, "2" to send a fax" and how set when the calling person press "1"--> connection to the telephone plugged into JACK01, when the calling person press "2"--> connection to fax, plugged into JACK06?
vogis is offline   sendpm.gif Reply With Quote
Old July 11th, 2009   #8 (permalink)
Moderator
 
sncsnc's Avatar
sncsnc is Tired

Activity Longevity
17/20 20/20
Today Posts
0/0 sssss1630
Location: The Berkshires Western,MA
Rep Power: 9sncsnc is on a distinguished road
Gender:
Country:
read the operators guide in the index under o for
ogm is recorded thru jack ones apt .
sncsnc is online now   Reply With Quote
Old July 11th, 2009   #9 (permalink)
Moderator

Activity Longevity
12/20 14/20
Today Posts
0/0 ssssss630
Location: NW Ohio
Rep Power: 6Cnavarro is on a distinguished road
Gender:
Country:
Quote:
Originally Posted by vogis View Post
Thank you very much! It's working well, but I can't find "idle line preference"...

Where I can find "idle line preference" in "Maintenance Console"?

Now, next question: how record OGM "Welcome in ... Please press "1" to talk, "2" to send a fax" and how set when the calling person press "1"--> connection to the telephone plugged into JACK01, when the calling person press "2"--> connection to fax, plugged into JACK06?
If your goal is to learn the system, is there any reason why you choose to not read the manual from cover to cover?

What happens if your instructor asks you how did you set it up, or to program a speed dial in location 47 for the local pizza parlor?

Are you going to ask him to wait while you go to the inernet and ask us?

RTFM All 4 of them.
Cnavarro is offline   sendpm.gif Reply With Quote
Old July 12th, 2009   #10 (permalink)
Junior Member

Activity Longevity
0/20 2/20
Today Posts
0/0 ssssssss4
Location: Warsaw
Rep Power: 0vogis is a newbie
Gender:
Country:
I have only guide about programming via system phone...
I'm not waiting for complete solution.
It's nice to receive an advice- it shows direction for further seaching



I think I know how to do it. I will test on monday.
I don't have any instructor, I'm learning it for myself, just for fun in scientifc circle

I'm studing mechatronics, so unfurtunately don't have enough knowledge about telecomunication systems. But Wikipedia and this forum are very helpful.

Anywey thank you very much for all helpfull advices!

Last edited by vogis; July 12th, 2009 at 07:32 AM.
vogis is offline   sendpm.gif Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Tes824 konstantinos Panasonic 2 August 3rd, 2008 02:35 PM
TES824 RUN LED is red AlexRigholt Panasonic 6 May 26th, 2008 03:41 PM
Kx-tes824 hotfuzz0119 Panasonic 6 May 23rd, 2008 02:38 AM
Tes824 AstroGuru Panasonic 3 February 13th, 2008 04:10 PM


All times are GMT -4. The time now is 09:00 PM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.2.0
Copyright (c) www.pbxinfo.com - PBX Info | Free PBX, PABX, IP PBX, VOIP and Telephone Information Resource Forum - Avaya / Nortel, Cisco, Panasonic, Mitel, ShoreTel, more...