Location: UAE (United Arab Emirates) Rep Power: 3 ![]() | TDA 600 Extension Plan problem hi to every one I am going to install Panasonic KXTDA 600 PBAX with the Expansion shelf KXTDA 620 in hotel. IN this i have 14 floors and each floor having 14 rooms means 196 total rooms.All Extension are analog. Cusstomer wants the Extension number should be same as the room number.eg Room NO 101 Extn 101. If i use 3 digit Extn number then i can configure only up to 9 th floor. At 10 th floor what should ber the Extesion number. So tried the 4 digit Extension plan, SO for Room No 101 Exten 1101.Now here my problem starts at floor number 11th,bcoz i have already given the Extn no1101 at first floor. I hope so i have explained the problem properly and suggestion regarding this issue will really apperciated. Thanks in Advance | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Moderator ![]() JulianW is drinking coffee.
Location: 254.45 miles from Tiverton, Devon (ENGLAND) Rep Power: 9 ![]() | I suppose it will depend on how they have numbered their rooms? Some hotels here would number their rooms 1 - 196, others number them with the floor number followed by a straight run of 1 - 14 on each floor. Which scheme does your hotel follow? | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Junior Member ![]()
Location: UAE (United Arab Emirates) Rep Power: 3 ![]() | Extension Plan Hi In hotel they are using the plan number in this way 1st floor 101-114 2nd floor 201-214 3rd floor 301-314 4th floor 401-414 5th floor 501-514 6th floor 601-614 so on 10 th floor 1001-1014 Thanks in advnce | ||||||||
| | |
| | #7 (permalink) | ||||||||
| Junior Member ![]()
Location: UAE (United Arab Emirates) Rep Power: 3 ![]() | Suggestion Dear SNCSNC We can make the code for operator is 0.But as it is mention above if i make 3 digit and 4 digits Extension numbering plan,how system will understand the difference between Extension number 101 and 1101? I thinks this feature is not available in Panasonic Any suggestion in this matter will be really appericiated thanks in advance | ||||||||
| | |
| | #8 (permalink) | ||||||||
| Senior Member ![]()
Location: York Rep Power: 6 ![]() | You cannot have a number plan like this:- 1st floor 101-114 2nd floor 201-214 3rd floor 301-314 4th floor 401-414 5th floor 501-514 6th floor 601-614 so on 10 th floor 1001-1014 101 would conflict with 1001, etc. In my opinion the best solution would be a 4 digit numberin plan like this:- 1st floor - 1101 to 1114 2nd floor - 1201 to 1214 3rd floor - 1301 to 1314 etc 10th floor - 2001 to 2114 11th floor - 2101 to 2114 12th floor - 2201 to 2214 etc I know this isn't exactly what you want but it's a good compromise Badger | ||||||||
| | |
| | #9 (permalink) | ||||||||
| Moderator ![]()
Rep Power: 5 ![]() | Iqbal The best solution could be the one proposed by sncsnc , provided that you have to assign a digit other than 0 ZERO to call the operator , and it is very common in Panasonic to use 9 for operator, and your room numbering will be from "0101-0114 ,0201-0214,.....,1401-1414".Here the first 2 digits will be the floor number, and the other 2 digits will be the room number. Last edited by AbuSuhail; 12-03-2006 at 01:07 PM. | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Matworx setting up new extension problem | DaveMNCPA | NEAX 2000 IVS(2)/ IPS | 8 | 10-26-2006 04:11 PM |
| 10XX calls will not go through | 612moto | Meridian Systems | 74 | 08-08-2006 10:48 AM |
| Really Strange MICS/AA/Voice Mail problem | lgherb | BCM and Norstar | 5 | 04-06-2006 09:30 AM |
| VoIP - Plan A vs Plan B | FreedomFireCom | VOIP Talk | 0 | 05-19-2005 10:42 AM |
| QSIG between Nortel & IPC | Twisted | Meridian Systems | 8 | 09-21-2004 02:30 PM |