Rep Power: 6 ![]() | The configuration as below , good luck. LD 97 REQ:CHG TYPE XPE XPEC xx (controller number) LOC xxxxx (any) REQ: CHG TYPE SUPL SUPL 12 SLOT L or R ( card inserted slot, by default L) SUPT <CR> XPE0 xx 0 3 ( SHELF 0 controller number, from segment0 , to segment3) XPE1 yy 0 1 ( SHELF 1 controller number, from segment0 , to segment1) | ||||||||
| | |
![]() |