Pms

I have permanent locked out status on extensions lines on some ONS 16 cards in a peripheral cabinet connected to an 3300 MXe. I assigned unused PLID positions which works ok. The problem is that the guest names from the PMS are not updated. Should I reboot the MXe or Disable and Enable the PMS to get the names updated as they are still showing in the old PLID
telecomtrust is offline   sendpm.gif Reply With Quote
Old November 5th, 2009   #2 (permalink)
Junior Member

Activity Longevity
0/20 2/20
Today Posts
0/0 sssssss13
Location: wigan
Rep Power: 0paul bennett is a newbie
Gender:
Country:
if you have moved the exts hasnt the class of service changed ?
paul bennett is offline   sendpm.gif Reply With Quote
Old November 5th, 2009   #3 (permalink)
Moderator
 
acejavelin's Avatar
acejavelin is a high-tech, heavy metal redneck!

Activity Longevity
11/20 4/20
Today Posts
0/0 ssssss620
Location: North Dakota
Rep Power: 2acejavelin is on a distinguished road
Gender:
Country:
Verify the COS for the room extensions is correct (using COS1 on a regular basis for Rooms in hopitality environments usually eliminates this issue). Then if you know the PMS system is functioning, have them issue an "Interface Resync" command to synchronize the PMS and 3300 systems. You could also have the front desk do a "Move" in the PMS system of these room, move it to a vacant room then move it back, this will usually update those rooms as well.

You could also try this command from the maintenance terminal (you may have to turn off AUTO COMPLETION), it works in the SX2000 so I would assume it will work in the 3300:

PCB KILL PROG pmsmgr

You should get a response that the program was killed. Then do a PCB STAT ALL and verify the process restarted, if it did not, issue this command:

PCB CREATE PROG pmsmgr

Careful using PCB, issued incorrectly it could cause, lets just say, erratic behavior of the system.

Of course, a RESET SYSTEM command works too, but not all PMS vendors support the 3300's RQINV request inventory command to resync the databases, so you may have to get the property manager or PMS tech support to issue a resync command anyway...
__________________
Telephony users cannot gain anything without first giving something in return. To obtain a useful feature, a feature of equal value must be lost.

This is Telephony’s First Law of Equivalent Exchange.

Last edited by acejavelin; November 5th, 2009 at 02:38 PM.
acejavelin is offline   sendpm.gif Reply With Quote
Old November 5th, 2009   #4 (permalink)
Senior Member

Activity Longevity
11/20 13/20
Today Posts
0/0 ssssss416
Rep Power: 5bobcheese is on a distinguished road
Gender:
Country:
depending on the version of software check either the COS for the option 'hotel room extension' set to yes or if R9 (I think) or newer then check that the ext number is in the 'guest room assignment' form. If the ext is not set as a bedroom by one of these two ways then it wont allow the PMS to check in/out
bobcheese is offline   sendpm.gif Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


All times are GMT -4. The time now is 04:14 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.2.0
Copyright (c) www.pbxinfo.com - PBX Info | Free PBX, PABX, IP PBX, VOIP and Telephone Information Resource Forum - Avaya / Nortel, Cisco, Panasonic, Mitel, ShoreTel, more...