| Junior Member
Rep Power: 0 ![]() | connect analog phone to 3300 CXI what should i do if i want to activate the LS ports and use analog phone .. i have the line from my service provider and i am sure it works .. iconnect it to one of the 6 LS ports at the back of the 3300 icx .. what is the configuration should i do to receive calls on my ip phones and how i could register the voice that should first direct the callaer to dail which number to convert him to my internal ip phones | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member ![]()
Rep Power: 0 ![]() | (1) program your "Trunk Service Assignment " form. Set set the day/n1/n2 to ring where ever you want it to go. (2) program the trunk in the "analog trunk assignment" form. Be sure to give it the Trunk Service number you assigned in step 1 above. (3) plug line in to 3300. (4) test. Dry_aquaman | ||||||||
| | |
| | #3 (permalink) | |||||||||
| Junior Member
Rep Power: 0 ![]() | Quote:
waht numbers should i put in the fields ? | |||||||||
| | |
| | #4 (permalink) | |||||||||
| Moderator ![]() ![]() acejavelin is a high-tech, heavy metal redneck!
Location: North Dakota Rep Power: 2 ![]() | Quote:
------------------ CO Trunk Circuit Descriptor Assignment (add a new one, major things noted) Number: 1 Line Start Type: Loop <= For loop start trunks Post Call Metering: No Guard Timer: 1500 Calling Party Disconnect: No Dictation Trunk: No Ignore Far End Disconnect: No Disconnect Timer: 500 Ignore Far End Reversal During Seizure: Yes Ringing Expected: Yes <= Make sure to set this Seize Timer: 10 Address Signalling: DTMF Fake Answer Supervision After Outpulsing: Yes Ignore Answer Supervision: Yes Release Supervision Expected: Yes Audio Inhibit Until Answer Supervision: Yes High Loss Option: No Balance Network Setting: National Complex Trunk Category: Short Perform seize test on out-of-service trunks: Yes Ground Condition During Busy Out: Removed First Meter Pulse Is Answer: No Minimum Ring Detection Timer: 200 Drop Digit Rcvr for Outgoing Audio Before Ans Sup: No Flash Timer: 300 Call Clearing Signal: Disconnect AC Impedance: National CLASS Trunk: Yes <= Yes if CID is provided by telco Milliwatt Tone: Silence Tone: ------------- Trunk Service Assignment (pick an unused number): Trunk Service Number: 1 Release Link Trunk: No Class of Service: 7 (Will vary depending on setup) Class of Restriction: 1 (Will vary depending on setup) Baud Rate: 300 Intercept Number: 1 Non-dial In Trunks Answer Point - Day: 250 <= Where calls ring in to Day mode Non-dial In Trunks Answer Point - Night 1: 250 <= Where calls ring in to Night 1 mode Non-dial In Trunks Answer Point - Night 2: 275 <= Where calls ring in to Night 2 mode Dial In Trunks Incoming Digit Modification - Absorb: (leave blank for LS trunks) Dial In Trunks Incoming Digit Modification - Insert: (leave blank for LS trunks) Trunk Label: <name of trunk, optional> -------------------- Analog Trunk Assignment (select appropriate one that you will connect line to) Cabinet: 2 Shelf: 1 Slot: 1 Circuit: 5 Card Type: Hybrid 4 ONS 6 LS Trunk Number: 1 <= Must be unique Trunk Service Number: 1 <= From Trunk Service Assignment above DTS Service Number: Circuit Descriptor Number: 1 <= From Circuit Descriptor assignment above Interconnect Number: 1 Tenant Number: 1 Balance Network Setting: National Complex Trunk Category: Short Auto Select: No Milliwatt Trunk Number: CO Telephone Number: --------------------- This should be all you need to program a LS trunk in your system, hope it helps. This is generally something a vendor should do if you are not familiar with it or it has never been setup before in your switch. This depends largely on the customer, but generally speaking, customers make simple moves and changes that are set or group based or do not require hardware changes such as system speed dials, hunt group members, button mapping, adding/swapping IP extensions, etc. If hardware changes are involved such as connecting new trunks that were not defined previously and the administrator is not familiar with the programming involved, I recommending getting a technician from a authorized vendor involved to do this work for you. __________________ Telephony users cannot gain anything without first giving something in return. To obtain a useful feature, a feature of equal value must be lost. This is Telephony’s First Law of Equivalent Exchange. | |||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| connect IP phones from 3300 CXI through fiber optic | 3300CXIuser | Mitel | 11 | May 27th, 2009 03:05 PM |
| 3300 Analog Stations get stuck in MOH | acejavelin | Mitel | 7 | March 26th, 2009 12:46 PM |
| Mitel 3300 connect to 9751 | mbsbooks | Siemens | 1 | September 21st, 2007 07:28 PM |
| phone configuration on 3300 ICP | JB007 | Mitel | 4 | April 22nd, 2007 12:12 AM |
| 3300 ICP phone registration | switch | Mitel | 3 | October 24th, 2004 08:43 PM |