| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: compatibility, dmid, integration, octel, qsig |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Junior Member ![]()
Location: Chlt-NC Rep Power: 7 ![]() | Has anyone heard of any issues with using a DMID (FLT-N cards on Octel) integration in conjunction with Qsig? A friend of mine mentioned a problem he was having trying to send MWI notification across the QSIG pipes to an IPC system. Supposedly IPC has an engineering bulletin in regards to this. I did not think it would be an issue since MWI is easily piped across PRI's. Thought the feature would be easily ported to QSIG. Thanks | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member ![]()
Location: Chlt-NC Rep Power: 7 ![]() | QSIG and Octel DMID integration compatibility I asked too quick. Found a solution on the NN website. One of the "Design Intent" replies. The solution indicates that QSIG is not compatible with integrations using MIK / MCK for setting and clearing MWI. Solution is to install a MerMail or Call Pilot. So much for QSIG opening the doors to multi vendor interoperability. Too bad the M1 can't do an SMDI integration, there wouldn't be an issue then. | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Senior Member Fletch is Nortel E911 PLM
Location: NORTEL - NJ Rep Power: 7 ![]() | Actually this will work if configured correctly under the proper topology and the proper RCAP settings on the DCH. __________________ Fletch Nortel Emergency Services PLM For more on Nortel E911 Solutions on the web: http://nortel.com/e911 Check out this month's E911 Talk podcast at Nortel E911 Talk Podcasts | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | Does the PINX DN of the local Meridian node need to be reflected in the Octel? (or CallPilot for that matter) The reason I ask is that I was reading the following in the NTP's and it seems to indicate that this is the case. It also references a message center PINX, which I would assume would be the pilot number for the Octel (or CallPilot)? DOC 533-3001-380 Standard 1.0 October 2003 Page1354 The MWI is transported in the following manner: 1. A Meridian Message Center (for example, CallPilot) sends an MWI message to the Meridian Message Center Private Integrated Services Network Exchange (PINX) that an unheard VoiceMail message exists for a user. The user is located in a different multi-vendor Private Integrated Services Network (PISN). 2. The Message Center PINX telephones up a connection to the multi-vendor Message Center PINX, possibly through one or more transit PINXs. -Thanks! | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |