| Guest
| Ok Here is the situation. I have had the system up and running after some previous issues with continuous ringing on some of the TNs. It has been about 3 with no problems then this morning a BSD090 MAIN wass issued. Which from what I understand is a power fault in the Main cabinet following this one of the extensions started it continuous ringing nonstop. If you hang up the phone it starts ringing very lightly at first untill finally the ringing is at it's peak level. Shortly after the BSD090 there was a NWS401 6: -0 -2 which is ok because these two lines do not have a phone on them. they are not being used at this time. but what has me confused is the Power fault in the MAIN cabinet. There was no power outtages last nite. Anyone have any idea what this might be. | ||||||||
|
| | #2 (permalink) | ||||||||
| Guest
| BSD Error Help Ok in addition to this problem I have also just received The following ERR 5306 401F 0410 (Telling me that a number was dialed with more than 10 digits in it) TIM0000 20:23 4/0/0 CPU 0 I'm including this in hopes that is may give an indication of what may be happening. Thanks for your alls help | ||||||||
|
| | #3 (permalink) | ||||||||
| Guest
| I am still getting the BSD090 Following each and everytime the phones start calling themselves and other extensions (Ghost in the machine) At this point I am suspecting the main power supply in the main cabinet since this is what powers the phones and the signal lamps. Any Suggestions? | ||||||||
|
| | #4 (permalink) | ||||||||
| Senior Member ![]() gei_spot is going phishing
Location: Somewhere in this vast universe on a little rock that looks like a grape. Rep Power: 12 ![]() | Waht type of system? OPT 11/51/61/81? what is showing on your MAINT DISPLAY? Is it one loop or multiple loops? Need more info. | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Guest
| Option 11c system with 2 shelves. Maint display shows the following Exactly as displayed on the Maint display ---------------------------------- AUD000 BSD090 MAIN BSD PWR OK NWS401 6 : -0 -2 ERR5306 401D 0410 TIM0000 22:07 5/0/0 CPU 0 AUD000 BSD090 MAIN BSD POWER OK NWS401 6 : -0 -2 AUD000 AUD000 ---------------------------------- This is the only thing displayed there are no other indications that there is a problem. Accept for a few extensions that ring constantly and if you check the line there is a (motor boating) sound on the line. As a reference point the lines ringing do NOT corespond to the NWS401 they are different TN's | ||||||||
|
| | #6 (permalink) | ||||||||
| Senior Member ![]() gei_spot is going phishing
Location: Somewhere in this vast universe on a little rock that looks like a grape. Rep Power: 12 ![]() | I would start by running these test, If your problem persist then I would try and reseat the SSC card. BSD0090 The program has detected a power fault indication. Action: Check power monitor indicators. If there is a power failure but no fault is found, the minor alarm lamp lights on the attendant console. If a power fault has been detected and the overlay area is idle, then LD 45 is run in background. To restore the regular background programs defined in LD 17, let LD 45 run twice and issue the clear major alarm command (CMAJ) from LD 30, LD 34, LD 35, LD 54 or LD 92 | ||||||||
| | |
| | #9 (permalink) | ||||||||
| Guest
| Ok, This is gonna sound funny but.. here it some info i've found out playing with the system and looking around **** Hotel Setup **** Card 6 Digital Line Card Units 0 1 2 Console extensions 600 602 and 604 0 and 2 are disabled because there is nothing on them. unit 1 is the main at the front desk. Units 14 and 15 say (PWR) I Hardware Disabled and ReEnabled Card 6 Run Maintenace twice and everything cleared up and is ok Also Increased airflow in the room because it was a little too hot in the room Right now everhting is running with no problems However when running LD 35 and typing DSPL It reports 81 and that is it Recently since then I have gotten an IOD041 Even with this error everthing is still functioning properly. What does 81 mean in the DSPL | ||||||||
|
![]() |