| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: call, integration, manager |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Senior Member
Location: Duvall, WA Rep Power: 5 ![]() | Anyone done a M1 to Cisco call manager integration using PRI? What kind of interface did you use for the PRI? What kinds of emulation can the Cisco do? We're trying D100 right now but seem to start building up bug1369's. Customer is running a script to disable and then re-enable the DCH each morning to band-aid this "problem". | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Senior Member
Location: Lou, KY Rep Power: 9 ![]() | I think that I just posted this very same question only worded it a bit differently. Check out my thread and see if we are talking the same language. Maybe we could collaborate on a solution. If you are currently going through this I could most definately learn from your pain.... I mean experiences. rlc | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Senior Member ![]()
Location: Somewhere in this vast universe on a little rock that looks like a grape. Rep Power: 11 ![]() | Tim I just posted something here http://nortel.pbxinfo.com/index.php?...ewtopic&t=1247 | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Senior Member
Location: Duvall, WA Rep Power: 5 ![]() | Post General Telecom Questions Here.. Here's the dch info from one system ADAN DCH 3 CTYP MSDL GRP 2 DNUM 12 PORT 3 DES xxxx USR PRI DCHL 65 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT IFC D100 SIDE USR CNEG 1 RLS ID 36 RCAP ND2 MBGA NO T200 3 T203 10 N200 3 N201 260 K 7 ADAN DCH 6 CTYP MSDL GRP 2 DNUM 13 PORT 2 DES CALLMGR2 USR PRI DCHL 67 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT IFC D100 SIDE USR CNEG 1 RLS ID ** RCAP ND2 MBGA NO T200 3 T203 10 N200 3 N201 260 K 7 ADAN DCH 11 CTYP MSDL GRP 3 DNUM 14 PORT 3 DES callmgr4 USR PRI DCHL 17 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT IFC D100 SIDE USR CNEG 1 RLS ID 36 RCAP ND2 MBGA NO T200 3 T203 10 N200 3 N201 260 K 7 | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Senior Member
Location: Duvall, WA Rep Power: 5 ![]() | Trunk tnbs TN 065 01 TYPE TIE CDEN SD CUST 0 TRK PRI PDCA 1 PCML MU NCOS 6 RTMB 2 1 B-CHANNEL SIGNALING TGAR 4 AST NO IAPG 0 CLS CTD DTN CND WTA LPR APN THFD HKD P10 VNL TKID DATE 19 MAR 2002 TN 067 01 TYPE TIE CDEN SD CUST 0 TRK PRI PDCA 1 PCML MU NCOS 6 RTMB 8 1 B-CHANNEL SIGNALING TGAR 4 AST NO IAPG 0 CLS CTD DTN CND WTA LPR APN THFD HKD P10 VNL TKID DATE 5 DEC 2003 TN 017 01 TYPE TIE CDEN SD CUST 0 TRK PRI PDCA 1 PCML MU NCOS 6 RTMB 8 24 B-CHANNEL SIGNALING TGAR 4 AST NO IAPG 0 CLS CTD DTN CND WTA LPR APN THFD HKD P10 VNL TKID DATE 5 DEC 2003 | ||||||||
| | |
| | #7 (permalink) | ||||||||
| Senior Member
Location: Duvall, WA Rep Power: 5 ![]() | rdbs TYPE RDB CUST 00 ROUT 2 DES ANCJAIL TKTP TIE ESN NO CNVT NO SAT NO RCLS EXT DTRK YES DGTP PRI ISDN YES MODE PRA IFC D100 SBN NO PNI 00001 NCNA YES NCRD NO CHTY BCH CTYP NPA INAC NO ISAR NO DAPC NO BCOT 0 DSEL VOD PTYP PRI AUTO NO DNIS NO DCDR NO ICOG IAO SRCH RRB TRMB YES STEP ACOD 8302 TCPP NO PII NO TARG CLEN 1 BILN NO OABS INST ANTK SIGO STD ICIS YES TIMR ICF 512 OGF 512 EOD 13952 NRD 10112 DDL 70 ODT 4096 RGV 640 GRD 896 SFB 3 NBS 2048 NBL 4096 TFD 0 DRNG NO CDR YES INC YES LAST YES QREC NO OAL YES AIA NO PAGE 002 OAN YES OPD NO NATL YES MUS YES MRT 18 RACD NO FRL 0 0 FRL 1 0 FRL 2 0 FRL 3 0 FRL 4 0 FRL 5 0 FRL 6 0 FRL 7 0 OHQ NO OHQT 00 CBQ NO AUTH NO TTBL 0 PLEV 2 ALRM NO ART 0 SGRP 0 AACR N TYPE RDB CUST 00 ROUT 8 DES ADC_CALLMGR TKTP TIE ESN NO CNVT NO SAT NO RCLS EXT DTRK YES DGTP PRI ISDN YES MODE PRA IFC D100 SBN NO PNI 00000 NCNA YES NCRD NO CHTY BCH CTYP NPA INAC NO ISAR NO DAPC NO BCOT 0 DSEL VOD PTYP PRI AUTO NO DNIS NO DCDR NO ICOG IAO SRCH LIN TRMB YES STEP ACOD 8308 TCPP NO PII NO TARG 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 CLEN 1 BILN NO OABS INST ANTK SIGO STD ICIS YES TIMR ICF 512 OGF 512 EOD 13952 NRD 10112 DDL 70 ODT 4096 RGV 640 GRD 896 SFB 3 NBS 2048 NBL 4096 TFD 0 DRNG NO CDR YES INC YES LAST NO QREC NO OAL YES AIA NO PAGE 002 OAN YES OPD NO NATL YES MUS YES MRT 18 RACD NO FRL 0 0 FRL 1 0 FRL 2 0 FRL 3 0 FRL 4 0 FRL 5 0 FRL 6 0 FRL 7 0 OHQ NO OHQT 00 CBQ NO AUTH NO TTBL 0 PLEV 2 ALRM NO ART 0 SGRP 0 AACR NO | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Changing the number a set is forwarded to from off site. | pcutler | Meridian Systems | 7 | 11-28-2007 10:56 AM |
| SPRE codes | ycoder | Meridian Systems | 11 | 12-11-2006 12:29 AM |
| FFC's not working | switch | Meridian Systems | 4 | 04-17-2003 07:51 AM |
| Trunk to Trunk connection woes... | Hi-Tech | Meridian Systems | 2 | 02-05-2003 07:25 PM |