| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: bosssecretary, problem, setup |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Guest
| I want to program two 2616 sets to work in boss-secretary setup, in fact they used to work that way but the user asked to the former programmer to change them so the BFS key in the secretary's set not to show when her boss was using the phone, but now there is a new boss who wants it the normal way, I checked the programming and it is supposed to work, but I'm missing something like a Class of Service or something. Where in the NTP's can I find this? I could't find it in the "Software feature guide" books; it's an op81C here are the print outs : DES SECR TN 006 0 04 14 TYPE 2616 CDEN 8D CUST 0 AOM 0 FDN 31000 TGAR LDN NO NCOS SGRP 0 RNPG SCI 0 SSU LNRS 16 XLST 1 SCPW SFLT NO CAC 0 CLS TLD FBA WTA LPR PUA MTD FNA HTA ADD HFA MWA AAD IMD XHA IRD NID OLD VCE DRG1 POD DSX VMD CMSD CCSD SWD LNA CNDA CFTD SFD MRD DDV CNID CDCA ICDA CDMD LLCN MCTD CLBD AUTU GPUA DPUA DNDA CFXA ARHD CLTD ASCD CPFA CPTA ABDD DELD CFHD FICD NAID UDI RCC HBTD AHA IPND DDGA NAMA MIND PRSD NRWD NRCD NROD EXR0 USRD ULAD CCBD RTDD OCBD FLXD FTTU DNDY DNO3 CPND_LANG ENG RCO 0 BFTN 002 0 04 14 HUNT 000 LHK 1 PLEV 02 AST IAPG 0 AACS NO ITNA NO DGRP DNDR 0 KEY 00 SCR 32000 0 MARP 01 SCR 470008 0 MARP 02 BFS 002 0 04 14 03 BFS 036 0 04 08 (it screens another set but it isn't reciprocal) 04 AO6 05 TRN 06 CFW 12 07 08 09 HOT D 2036 2247 MARP 0 10 DSP 11 HOT D 2039 2348 MARP 0 12 RGA 13 14 MWK 31000 15 DATE 2 AUG 2002 ------------- DES BOSS TN 002 0 04 14 TYPE 2616 CDEN 8D CUST 0 AOM 0 FDN 31000 TGAR LDN NO NCOS SGRP 0 RNPG 0 SCI 0 SSU XLST 2 SCPW SFLT NO CAC 0 CLS TLD FBA WTA LPR MTD FND HTA ADD HFA MWA AAD IMD XHA IRD NID OLD VCE DRG4 POD DSX VMD CMSD CCSA-CSI SWD LND CNDA CFTD SFD MRD DDV CNID CDCA ICDA CDMD LLCN MCTD CLBD AUTU GPUA DPUA DNDA CFXA ARHD CLTD ASCD CPFA CPTA ABDD DELD CFHD FICD NAID UDI RCC HBTD AHA IPND DDGA NAMA MIND PRSD NRWD NRCD NROD EXR0 USRD ULAD CCBD RTDD OCBD FLXD FTTU DNDY DNO3 CPND_LANG ENG RCO 0 BFTN 004 0 05 04 006 0 04 14 HUNT 000 LHK 1 PLEV 02 AST IAPG 0 AACS NO ITNA NO DGRP DNDR 0 KEY 00 SCR 33853 0 MARP 01 SCR 470007 0 MARP 02 BFS 006 0 04 14 03 04 AO6 05 TRN 06 CFW 16 32000 07 08 DIG 2 10 R 09 HOT D 2036 10 DSP 11 HOT D 2039 12 SCC 0025 13 DIG 5 01 R 14 MWK 31000 15 DATE 17 OCT 2002 Thanks PD because of the company´s Policy I changed nuerical values. | ||||||||
|
| | #2 (permalink) | ||||||||
| Senior Member ![]() Rachelle is curious
Location: Lou, KY Rep Power: 9 ![]() | I believe that your CLS should reflect BFEA or even BUZZ. Look in your Administration Guide under LD 11. Then you can cross reference in the feature guides for more details on implementation. rachelle | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Guest
| It turned out to be a misunderstood service call, the above programings are ok, but the boss has two 2616 in his office and the secretary wanted to be able to see whenever her boss is using the 2nd set. which btw she could not see because ,although she has the tn in a BFS key the other set hadn't, so it works only if both sets have a BFS key of eachother tn. Thanks. | ||||||||
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Callpilot Apllication Problem | sneexy69 | Meridian Systems | 2 | 11-22-2003 11:23 AM |
| Call forward to secretary voicemail | mednickm | Meridian Systems | 3 | 04-01-2003 04:09 PM |
| BFS key Ringing and the Boss. | Meridian Systems | 6 | 02-24-2003 10:21 AM | |
| Strangest Problem Ever ? | markj39k | BCM and Norstar | 11 | 01-15-2003 09:11 AM |