| Junior Member
Rep Power: 0 ![]() | We are bringing up a new CS1000S in our lab and are having trouble getting the MC32S to take a download from the Signaling Server. We add the MC32S card in Element Manager and assign the IP address etc but when we go to save and transfer the download errors out. We have two cards acting the same way. Any ideas? Thanks, Mike | ||||||||
| | |
| | #4 (permalink) | ||||||||
| Junior Member ![]() Sinner has no status.
Rep Power: 0 ![]() | Getting the same problem of transferring. I upgrading PBX rls 4 to 4.5, it gets successful then SS to release 4.00.55.88 it also gots OK but when i downloaded new MC32 IPL software and unzipped it to flash of MC32 it wont boots to IPL rather goes to VXWorks prompt. Neither I can transfer Node properties to MC32, i also tried deleting node and transfer to MC32 but it also fails. SS and PBX patches are update. How could i upgrade this MC32 and why it wiont load IPL prompt? Any help in this regards will be very helpful. regards | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Senior Member ![]()
Rep Power: 0 ![]() | in vxworks mode...check the c drive is there and check the file are available in the FMD which is there in the MC card....if not...download the IPL software...which there in the format of xxxx.sa and rename it to EXEC and transfer it to c:/ and reboot the mc card... i hope this is will help you | ||||||||
| | |
| | #7 (permalink) | |||||||||
| Senior Member ![]()
Location: Moscow Rep Power: 0 ![]() | Quote:
You do not mistaken? MC32S is supported from rel. 5.X, but 1000S architecture in these rls is absent. | |||||||||
| | |
| | #8 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | We resolved the problem. It turned out that we were following the instructions in Element Manager and there is a set-up section where you are prompted to add the MC32S into the Signaling Server. After this was filled out and the transfer was initiated is where we saw the failure. The elements could not “start task”. We found out that this section was not required at all. The MC32S was already operational and did not require us to configure this page. We ended up deleting all of the cards from the Signaling Server. The correct procedure is to go to Media Gateways and add your IPMG cards. The documentation shows the initial step we took, which was wrong. I did mis-state the system as CS1000S. It is a CS1000E. Thanks for your posts. | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| MC32s | aha | Meridian Systems | 8 | October 30th, 2008 09:02 AM |
| Problem with mc32s in rls5.00 cs1000e | sreejeshpps | Meridian Systems | 7 | July 25th, 2008 10:27 AM |
| New MC32S | mertech | Meridian Systems | 2 | July 9th, 2008 11:49 AM |
| mc32s | dnightingale | Meridian Systems | 0 | December 12th, 2007 12:58 PM |
| OXO V3 download ? | Marc | Alcatel-Lucent | 1 | April 17th, 2006 06:08 AM |