| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: bris, isdn |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Junior Member ![]()
Location: UK Rep Power: 7 ![]() | Food and Drink Facts On the site I'm working on at the moment, we have an Option 81C with numerous Fiber Remotes. All of these remotes have a SILC card in them for provision of ISDN BRI lines. Problem is that these lines have a tendancy to die; disabling and re-enabling the relevant MISP with a force download always brings these lines back into service. Does anyone have any thoughts on what could be causing this? I have to do this for each MISP at least once a week at the moment, and the end users go beserk when their video conferences don't work!! :laugh: The good news is I've just rolled out virtual office with 3903/4's, and it's working sweet (except we need to upgrade to 25.40 at some point to get the SCC feature for phantom sets lol). | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Junior Member ![]()
Rep Power: 7 ![]() | hicom 150 same here I even worked with etas after a while i gave up. its so random i think i remember a post where FLetch said he used these cards I would be interested if he has any insite YOOOOO Fletch __________________ WHAT DOES THAT HAVE TO DO WITH DIAL TONE??????????????????????????????????? | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Junior Member ![]()
Location: UK Rep Power: 7 ![]() | Thank GemTech, now a new question... Yip, seems to be completely random as to which MISP I have to FDL. I'm thinking of setting up a ProComm script to reset them all dialy at obsure morning hours as an attempt to reduce the amount of visible outages. I've actually had some guys from Kingston, and some guys from Nortel on site to look at this problem and they weren't able to come to a conclusion... | ||||||||
| | |
| | #7 (permalink) | ||||||||
| Junior Member ![]()
Rep Power: 7 ![]() | DISPLAY BASED ADD-ON CONTRAST? well i suppose fletch has no comment or hasnt read this post. oh well. just wondering if anyone has the isdn bri solution through the pbx where the misp cards does not go to sleep. it is pretty pathetic it seems that everyone has the problem yet still nortel doesnt have it resolved. __________________ WHAT DOES THAT HAVE TO DO WITH DIAL TONE??????????????????????????????????? | ||||||||
| | |
| | #8 (permalink) | ||||||||
| Junior Member ![]()
Location: UK Rep Power: 7 ![]() | Meridian Programming Crash Course I've been poking around, and not found anything yet :casstet: I'm going to raise a proper case with Nortel to get this looked into in more detail... so far I've had 5 of their engineers take a look at it, along with 2 Kingston engineers | ||||||||
| | |
| | #10 (permalink) | ||||||||
| Junior Member ![]()
Location: UK Rep Power: 7 ![]() | Patch description Hmmmmm... well I've been "playing" with it for the last few days, and all 4 of my MISPs have come up with the below error at least once whilst I've been working on them. I ordered a new MISP card in to replace one which fails all the time, and it could barely manage to stay up for 2 minutes. I have another brand new one sat on my desk now which I'm going to swap later. BRI813 MISP 32 BRIL: 0000FF00 0000FFFF 0000FFFC 000000BF 00006748 00000000 00000000 00000000 00000000 00000000 00000000 00000020 00000044 00000090 0000E606 00000000 MISP307 32 0000DEAD 0000A522 000000C0 00000000 00000044 00000007 00000000 0000FFFF 00000000 00000000 00000000 00000000 00000000 000000BC 0000DC7C 000000B7 0000C588 000000B7 0000C6A4 000000B7 0000C574 00000082 0000B924 000000B7 0000C6A4 00000000 00003704 00000080 00000000 00000000 00000000 00000000 00000000 00000000 00000001 00003F7C 0000FE7D 00001000 00000081 000098B0 0000B008 00001E8C 00000161 00003000 00004E75 00000020 00000044 00000020 00000044 00000000 00000044 00003010 00003010 00000081 000098B6 00000081 MISP101 32 MISP300 32 FROM: ENBL TO: SYS DSBL - SELFTESTS FAILED TIME: 09 10 REASON: 68020 BUS ERROR | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Connecting an ISDN PABX to Asterisk | rixride | Asterisk Systems | 0 | 03-11-2006 12:17 AM |
| ISDN PRI of avaya connecting ISDN PRI2 of nortel | Jedly@ | Definity Support | 2 | 03-13-2005 11:05 PM |
| ISDN U cards and termination devices | JohnnyGrep | BCM and Norstar | 1 | 02-15-2005 11:58 AM |
| ISDN BRI on a MICS help needed | martyatherton | BCM and Norstar | 1 | 07-28-2003 12:19 PM |