| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Junior Member ![]()
Location: Leeds Rep Power: 0 ![]() | Help! Unable to connect to Meridian Hi, I look after a Meridian opt 81C. I were in ld 20 removing old TN`s which were no longer active. I had removed a couple and then the hyperterminal window went absolutely bonkers. Every key I press just comes up as 0 . It is still popping up maintainence messages and the likes just not letting me do anything. No LD commands, logi,logo. Anyone have an ideas? as I have 40phones to create and put into Symposium Thanks Christian. Edit to add: I am using a com port and serial lead to connect to the Meridian. I also have a backup from last night. I have also tried rebooting the pc that I use to connect and unplugging the serial lead from it to. Last edited by ChristianZS1; 05-27-2008 at 10:37 AM. | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member ![]()
Location: Leeds Rep Power: 0 ![]() | DCH: 21 MAINT INDICATION TIME: 15:26:26 COUNTER VALUE 3 255 TIM001 15:28 27/5/2008 CPU 1 ERR183 0025 18 2 DCH: 50 MAINT INDICATION TIME: 15:29:28 COUNTER VALUE 3 255 DCH: 48 MAINT INDICATION TIME: 15 48COUNTER VALUE 3 255 DCH: 24 MAINT INDICATION TIME: 15 00COUNTER VALUE 3 255 DCH: 23 MAINT INDICATION TIME: 15 26COUNTER VALUE 3 255 00000SCH0600 TN 00 DTC001 00000000000000000000000000000 DCH: 15 MAINT INDICATION TIME: 15:34:28 COUNTER VALUE 3 255 00000000000000000000000000000000000000000000000000 000000000000000000000000000000 0000000000000000000000000000000 BUG4231 BUG4231 : 20 0 15 3 BUG4231 + 0471C390 0444387E 044432FE 043B1042 043B1230 BUG4231 + 043AF9A4 04422AD4 04422A0C 046482DC 04647D3C BUG4231 + 0464208E 04641096 04B513AA 04B510BE 04B51008 BUG4231 + 0DBB819E 00000000000000000000000000000000000000000000000000 000000000000000000000000000000 0000000000000000000000000000000000000000000000 What is displayed on screen. The 0`s are any keys that I try. | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Senior Member ![]()
Location: Duvall, WA Rep Power: 5 ![]() | err183 is a DNIS translation error DNIS calls cannot terminate because the IDC Translation is invalid, or the terminating station is not an ACD-DN Are you sure you are still logged in? Have you tried another tty port? | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Senior Member ![]()
Location: Duvall, WA Rep Power: 5 ![]() | If you are seeing maintenance traffic, I would say you have a good connection to the pbx. Leaving it disconnected for an hour should have timed out any bad password attempts. Do you have a modem connected to the pbx? Can you dial in? And, what do you get there? Have you somehow changed your communications setting for the hyperterminal session? Have you tried building a new hyperterminal session? | ||||||||
| | |
| | #6 (permalink) | |||||||||
| Junior Member ![]()
Location: Leeds Rep Power: 0 ![]() | Quote:
We have looked at the comm`s settings in the hyperterminal session and believe that nobody had changed it. I have tried building a new HT session but every key press shows up as 0 no matter what emulation I have had it set on. Are there any default settings which should let me in on HT? Is it likely to be the PC at fault? Thanks C. | |||||||||
| | |
| | #7 (permalink) | ||||||||
| Senior Member ![]()
Location: Duvall, WA Rep Power: 5 ![]() | I have seen issue with hyperterminal before wher I had to blow away the original session and build a new one. You need to be able to look at the ADAN information to see the com settings for a given tty port. Are you using the pc for anything other than access to the pbx? If so and it is working I would say no it is not the pc, if this is its only function try something else and see if the keyboard seems to be working OK. | ||||||||
| | |
| | #8 (permalink) | |||||||||
| Junior Member ![]()
Location: Leeds Rep Power: 0 ![]() | Quote:
The PC has the Call Logger software which is running fine and dandy on Com2, The Meridian HT port is com1 which does give the Maintainence info but nothing else other than type 0 no matter what key I press. I have tested all the keys in notepad and they all show up fine. | |||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| unable to get credential | bceballos | SIPX | 0 | 02-01-2007 10:05 AM |
| Siebel / CT Connect / Symposium / Meridian | kulasman | Contact Center Symposium and ACD | 0 | 10-30-2006 11:13 AM |
| Unable to Connect to server(Symposium) | jimz | Contact Center Symposium and ACD | 3 | 11-11-2005 08:47 AM |
| Unable to connect to AD8 Voice Mail | Pedrog | NEC | 2 | 08-01-2005 12:00 PM |
| Connect a meridian with Panasonic | gnrpatience | Meridian Systems | 1 | 07-24-2003 07:19 AM |