Rep Power: 0 ![]() | UNEQ Issue on OPT 11 System I hired a vendor to do some work at a remote location on our OPT 11 Nortel system (call Pilot) - the office made an addition and the vendor left me a voicemail stating that he punched down a phone to TN 15 4 and that I need to assign a DN to it. When I stat that port it shows UNEQ. Which if I remember right, tells me there is nothing plugged in correct? I have verified that she plugged a phone in. I'm looking at try to get his phone up and running but am stuck - any idea's or suggestions? | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Senior Member
Location: Far away Rep Power: 6 ![]() | you will need to add a spare number on 15 4 first find a spare DN LD 20 req prt type ludn cust x c/r till all your spare numbers are printed then select a spare LD 20 req chg type 2616 ( 2616 for a digital set or 500 for analog ) cust x TN 15 4 item key 0 scr xxxx ( this is the DN you have selected ) c/r till the end then go to LD 95 req new type name cust x dn xxxx then enter a name try that Last edited by colin : 04-07-2008 at 02:51 PM. | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | Thanks for the reply, I found a spare but you lost me on this section: LD 20 req chg type 2616 ( 2616 for a digital set or 500 for analog ) cust x item key 0 scr xxxx ( this is the DN you have selected ) c/r till the end I go to LD20 I put in chg I put 2616 for type because it is digital but then it asks for the TN - do I put in the 15 4 TN or the TN of the spare? | ||||||||
| | |
| | #8 (permalink) | ||||||||
| Senior Member
Location: Chicago -- CENTER OF THE UNIVERSE Rep Power: 10 ![]() | Yep sounds like vendor only did wiring but did not program the TN. Build a new TN or copy an existing and you should be good to go. As an aside I'd leave a message for this vendor not to send that tech out again. __________________ Dogs rollover Phones hunt | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| BCM 3.6 OLI issue | hawks08 | BCM and Norstar | 1 | 04-19-2007 11:38 PM |
| Carrier or phone system issue? Can;t not dial local prefix | zleviticus | BCM and Norstar | 4 | 02-22-2007 09:20 AM |
| Siemens System integration with thirdpary system | japanktrivedi | Siemens / Rolm | 4 | 07-18-2006 07:34 PM |
| Property Management System Issue | Chas2002 | Meridian Systems | 3 | 03-11-2003 04:07 PM |
| System limitation... this may be an ACD issue. | Rachelle | Meridian Systems | 2 | 02-20-2003 10:32 AM |