| |||||||||
![]() | | ||||||||
| |||||||||||||||
| |||||||||||||||
| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: e1 problem |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | E1 Disconnect Hi! Im having trouble with the company's newly installed Nortel Meridian Option11C CS1000. The PBX is a having a consisent problem regarding it's E1 communication to the other plant sites of the company. There's this BUG266, BUG9161, and BUG8990 by which all points to the clock synchronization of both PBXs. Although the documentation cd states that these cases are mostly minor, it really frustrates me that everytime there is a disconnection between plant sites I always enable the E1 card every now and then. I've checked the modems of both plant sites and were all ok, all cables were properly terminated. Any help would be deeply appreciated. Thanks! | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | E1 Disconnet Detailed Hi, I would like to revise my previous inquiry regarding my posted topic. I have 3 sites connected with E1 connections. Site 1 being the main pabx with 3 cabinets about 200 local ines. Site 2 with 1 cabinet having 56 local lines. Site 3 having 1 cabinet and 32 lines. Site 1 and site 2 is connected through an E1 50 pair copper wire installed about 10 years ago. Site 1 and site 3 is connected through an E1 50 pair copper wire installed about 2 years ago. Problem is the E1 connection of site 1 and site 2 is the one that often disconnects. The basic thing that i would do is check the modem of both sites, but it's ok. So I will disable and enable the E1 cards,that connect both sites. Then, the connection is back to normal. The problem is recurring and I have a hard trying to find out what could be the cause of this disconnection. Please help, any advice would be appreciated. Thnak you. | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Callpilot cannot disconnect! | Ric | Meridian Systems | 5 | 01-18-2007 08:32 AM |
| No answer disconnect | shankar | Meridian Systems | 13 | 09-11-2006 12:57 AM |
| Disconnect calls after a while. | TELEPATH | Meridian Systems | 3 | 09-10-2006 01:00 AM |
| Disconnect Supervision | Alison | Meridian Systems | 2 | 07-21-2005 02:37 PM |
| Disconnect Problems | morpheus | Meridian Systems | 11 | 02-14-2005 04:07 PM |