| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: pri, question |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Junior Member ![]()
Rep Power: 7 ![]() | PRI Question. We have a Tie route going to a special application ( Polycom Conference Bridge). The interface is D-100 ( recommended by vendor). When the bridge outcalls to a person needed in the conference the local carrier is not sending out the CLID. On DCH messaging we are sending out a valid CLID but the number plan is being flagged as unknown. 1. Outbound Polycom Conference call, CLID is not given to called person (Cinglur Telephone) notes: DCH 8 is PRI to Polycom conference bridge (D100 and Tie route configuration). DCH 1 is PRI to Verizon (for local calls) DCH 8 IMSG SETUP REF 00008C00 CH 25 11 TOD 13:55:39 CALLING #:4433943100 NUM PLAN: NUM UNKNOWN CALLED #:84102450178 NUM PLAN: NUM UNKNOWN DCH 1 OMSG SETUP REF 00000021 CH 28 9 TOD 13:55:39 CALLING #:4433943100 NUM PLAN: NUM UNKNOWN CALLED #:4102450178 NUM PLAN: E164 DCH 8 OMSG CALLPROC REF 00008C00 CH 25 11 TOD 13:55:39 DCH 1 IMSG CALLPROC REF 00000021 CH 28 9 TOD 13:55:39 DCH 1 IMSG PROGRESS REF 00000021 CH 28 9 TOD 13:55:39 PROGRESS: INBAND INFO OR PATTERN IS AVAIL 2. Outbound (from extension) telephone call, CLID does work DCH 1 OMSG SETUP REF 00000013 CH 2 19 TOD 15:52:57 CALLING #:4433945850 NUM PLAN: E164 CALLED #:4102450178 NUM PLAN: E164 DCH 1 IMSG STATUS REF 00000013 CH 2 19 TOD 15:52:57 CAUSE :USER INFO DISCARDED STATE : CALL INIT ST DCH 1 IMSG CALLPROC REF 00000013 CH 2 19 TOD 15:52:57 DCH 1 IMSG PROGRESS REF 00000013 CH 2 19 TOD 15:52:57 PROGRESS: INBAND INFO OR PATTERN IS AVAIL | ||||||||
| | |
| | #4 (permalink) | ||||||||
| Senior Member ![]() Rachelle is curious
Location: Lou, KY Rep Power: 9 ![]() | Ringing Phone without functions Your T1 in your PBX may be just fine. It may be a configuration issue with the Polycom itself not allowing the CLID to pass through. Verify your Polycom settings. rlc __________________ No matter where you go, there is the Ladies Love Marty Fan Club. :bow2: :bow2: :bow2: | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Senior Member Fletch is Nortel E911 PLM
Location: NORTEL - NJ Rep Power: 7 ![]() | Help with determining trunk route type Jim- The problem is that the Ploycom is generating the setup message with the CALLING NUMBER Information Element (IE) flagged as Unknown. This has nothing to do with your Meridian programming. In 25.40, Nortel added the CTON prompt to the RDB which lets you define the Type of Number (TON) to assign to the CALLING NUMBER IE. Unfortunately this is only available on EuroISDN routes, it won't help you on D-100. You need to go to Polycom, and tell them that they need to assign both the NUMBER PLAN TYPE nad TYPE OF NUMBER IE's on their outbound messaging. They are notorious for doing this on their GateKeeper's as well. Hope this answers your question. __________________ Fletch Nortel Emergency Services PLM For more on Nortel E911 Solutions on the web: http://nortel.com/e911 Check out this month's E911 Talk podcast at Nortel E911 Talk Podcasts | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Senior Member Fletch is Nortel E911 PLM
Location: NORTEL - NJ Rep Power: 7 ![]() | New Area Code Wanna push their buttons further? DCH 8 IMSG SETUP REF 00008C00 CH 25 11 TOD 13:55:39 CALLING #:4433943100 NUM PLAN: NUM UNKNOWN CALLED #:84102450178 NUM PLAN: NUM UNKNOWN If they sent the CALLED number TYPE OF NUMBER and NUMBER PLAN inofrmaion as a PUBLIC E.164, then you could turn on INAC on the RDB as well, and the user wouldn't have to dial the "8", and they would not have to send it either. When this is all fixed, the DCH Message will look like this: DCH 8 IMSG SETUP REF 00008C00 CH 25 11 TOD 13:55:39 CALLING #:4433943100 NUM PLAN: E164 CALLED #:4102450178 NUM PLAN: E164 <----Assuming INAC is on Then if you ever change AC1, the Polycom doesn't even need to know about it. Clean config. Minimal Problems. :laugh: Happy Campers! Easy to understand once broken down! __________________ Fletch Nortel Emergency Services PLM For more on Nortel E911 Solutions on the web: http://nortel.com/e911 Check out this month's E911 Talk podcast at Nortel E911 Talk Podcasts | ||||||||
| | |
| | #7 (permalink) | ||||||||
| Senior Member Fletch is Nortel E911 PLM
Location: NORTEL - NJ Rep Power: 7 ![]() | PRI Question. SO...... Now which one of you can tell me why: DCH 8 IMSG SETUP REF 00008C00 CH 25 11 TOD 13:55:39 CALLING #:4433943100 NUM PLAN: NUM UNKNOWN CALLED #:84102450178 NUM PLAN: NUM UNKNOWN Comming from the TIE line gets changed to: DCH 1 OMSG SETUP REF 00000021 CH 28 9 TOD 13:55:39 CALLING #:4433943100 NUM PLAN: NUM UNKNOWN CALLED #:4102450178 NUM PLAN: E164 <----Gee, this looks familiar! Going out the PRI to the PSTN??? __________________ Fletch Nortel Emergency Services PLM For more on Nortel E911 Solutions on the web: http://nortel.com/e911 Check out this month's E911 Talk podcast at Nortel E911 Talk Podcasts | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| NNC Alarm in TIE PRI | justzikle | Meridian Systems | 2 | 08-05-2006 04:31 AM |
| Internet PRI?? | justzikle | Meridian Systems | 1 | 07-15-2006 11:02 PM |
| Mitel 200EL PRI Name display question...help | KMAN11 | Mitel | 1 | 06-28-2006 09:39 PM |
| Auto dialing on all PRI Channel | justzikle | Meridian Systems | 3 | 04-05-2006 01:28 PM |