Option 11 25.40 - PBX Info :: Your Free PBX, PABX and Telephone Information Resource
Home | Register |    
 
Forums         |        Articles          |        Blogs         |      Software          |      Portals          |      Resource          |      Wiki      |    White Papers         
 
Go Back   PBX Info :: Your Free PBX, PABX and Telephone Information Resource > PBX SYSTEMS > NORTEL > Meridian Systems
   SEARCH  
     
User Name Password      
Save ?
Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications

Tags: ,


Reply
 
LinkBack Thread Tools Display Modes
Old 01-16-2007, 05:32 PM   #1 (permalink)
John McJunkin
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss67
Rep Power: 0John McJunkin is an unknown quantity at this point
Country:
Option 11 25.40

I am installing an option 11 with 25.40 software.
I can not get a new T1 to work. I have the TMDI card with the built on dch, I also installed a cc daughterboard on the TMDI card.
I have a test set that I can connect to the network side and then I can make calls from the test set. So doing that the network company says that they are good, but my switch does not come up.
I could use some help please.
thanks John
John McJunkin is offline   sendpm.gif Reply With Quote
Old 01-16-2007, 05:36 PM   #2 (permalink)
rixride
Admin
 
rixride's Avatar
rixride is replying to forum games...

Activity Longevity
4/20 20/20
Today Posts
0/0 sssss3132
Location: Dallas, Texas
Rep Power: 5rixride has much to be proud ofrixride has much to be proud ofrixride has much to be proud ofrixride has much to be proud ofrixride has much to be proud ofrixride has much to be proud ofrixride has much to be proud ofrixride has much to be proud of
Gender:
Country:
 
Is the PRI in alarm? If so what color?
__________________
-=Welcome to PBXInfo=-
-Become a PBXInfo Supporter
-Get more PM Space, Profile Picture, a Signature
-Add yourself to Pbxinfo's Frappr
-Find Nortel Software
rixride is offline   sendpm.gif Reply With Quote
Old 01-16-2007, 05:52 PM   #3 (permalink)
John McJunkin
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss67
Rep Power: 0John McJunkin is an unknown quantity at this point
Country:
red alarm
John McJunkin is offline   sendpm.gif Reply With Quote
Old 01-16-2007, 06:35 PM   #4 (permalink)
papa-bear
Moderator
 
papa-bear's Avatar
papa-bear is suffering from a pad thai lunch

Activity Longevity
10/20 14/20
Today Posts
0/0 sssss3343
Location: @home
Rep Power: 8papa-bear will become famous soon enough
Gender:
Country:
Do you have the unit properly grounded?

Had one once where the ground did not go back to the same box as the power for the switch came from and I could not get the alarm to go off. Had electricians run new ground and all started to work.

Was a strange solution but I had asked them to put the ground in specifically for this install and when I noticed it was not in the same electrical box it was the first thing in my mind when the PRI did not come up.

Had another one with OPX gear attached. When I grounded them to the system ground the PRI went out. When I lifted the ground and let them ground through the power outlets it came back up.

bizarre but true.
papa-bear is offline   sendpm.gif Reply With Quote
Old 01-16-2007, 08:57 PM   #5 (permalink)
John McJunkin
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss67
Rep Power: 0John McJunkin is an unknown quantity at this point
Country:
I have had grounding issues also, but not like you had. I will be back on site tomorrow and I will check that out
thanks John
John McJunkin is offline   sendpm.gif Reply With Quote
Old 01-17-2007, 11:37 AM   #6 (permalink)
John McJunkin
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss67
Rep Power: 0John McJunkin is an unknown quantity at this point
Country:
I check the grounding, not my problem though.
A bit more info. The company that I am working for decided to buy the new PRI from Time Warner, not the best idea as far as I am concerned but that is the way it is.
The dch will not come up. It is the same as usual programing, ni2-std-esf-b8s-clock,ext.
Need help with this please.
thanks John
John McJunkin is offline   sendpm.gif Reply With Quote
Old 01-17-2007, 12:45 PM   #7 (permalink)
WhereWolf
Senior Member
 
WhereWolf's Avatar
WhereWolf is sober (maybe....)

Activity Longevity
11/20 13/20
Today Posts
0/0 ssssss474
Rep Power: 4WhereWolf is on a distinguished road
Gender:
Country:
What are the inbound and outboard d-channel monitors saying?
Is auto recovery on or off?
If the service messages are on currently, you can try to turn them off - I've had cases where the telco setup was service messages on for 1 t1
and services messages off for another t1.

If the telco hasn't placed the D-Channel in an auto-recovery/establish mode, then you can try all day, but it won't come up without their assistance. You also need to verify that the Interface (Ni-2, ATT, Custom, etc... is the same on the telco side....)
Hope it helps...

Wherewolf
WhereWolf is online now   sendpm.gif Reply With Quote
Old 01-17-2007, 02:07 PM   #8 (permalink)
John McJunkin
Junior Member

Activity Longevity
0/20 8/20
Today Posts
0/0 sssssss67
Rep Power: 0John McJunkin is an unknown quantity at this point
Country:
I have worked with the telco, they have verified what they are sending to me. So even with their assisstance it did not come up. I then replaced the tmdi card and I spent yesterday trying to get it up but to no avail.
They said that they are sending ni-2, Std, b8s, etc.
thanks John
John McJunkin is offline   sendpm.gif Reply With Quote
Old 01-17-2007, 02:07 PM   #9 (permalink)
PP
Senior Member
 
PP's Avatar
PP is AN OLD ROLMEN WORKING ON NORTEL AND AVAYA

Activity Longevity
8/20 20/20
Today Posts
0/0 sssss1677
Location: MIAMI, FLA
Rep Power: 8PP will become famous soon enough
Place A Loopback On The Cable Before It Hits The Csu, Pins 1-2 To 4-5 And See If It Comes Out Of Red. Dch Will Not Come Up But Your Counters Should Be Clean
PP is offline   sendpm.gif Reply With Quote
Old 01-17-2007, 02:49 PM   #10 (permalink)
Rachelle
Senior Member
 
Rachelle's Avatar
Rachelle is curious

Activity Longevity
6/20 20/20
Today Posts
0/0 sssss3414
Location: Lou, KY
Rep Power: 9Rachelle is on a distinguished road
Country:
Are all DIP switches and Device Numbers confirmed and correct?
If you put a Loop Back on the I/O panel and loop the card itself, before hitting any cables, your T1 should come up in WRONG MODE. If it doesn't come up in WRONG MODE then there is a hardware or config problem within your PBX. From there, move the Loop back down the food-chain until you hit the CSU. Once you reach the CSU, it should then be up to the telco to provide service. They may need to dispatch to your site for proper testing.


rlc
__________________
No matter where you go, there is the Ladies Love Marty Fan Club. :bow2: :bow2: :bow2:
Rachelle is offline   sendpm.gif Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
cos option 11c Patricia Meridian Systems 3 03-07-2006 06:57 PM
Option 11 Meridian Mail Card Option Spanton Meridian Systems 2 03-03-2006 04:11 PM
Difference between an Option 11 and Option 61 radicalphoney NORTEL 2 10-12-2005 01:27 PM
Option 11 INI kleeg Meridian Systems 4 04-14-2005 02:05 PM
Option 11 to Option 61 connection betopizza Meridian Systems 3 02-02-2005 12:01 PM


All times are GMT -5. The time now is 12:03 PM.

Tags   |   Advertise    |    Media Partners   |    Admin   |   About us   |   Contact Us   |   RSS   

Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.0.0
Copyright PBXINFO LLC 2006