| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: help, nds, ni2, rcap |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Senior Member ![]() WhereWolf is sober (maybe....)
Rep Power: 4 ![]() | Need NI2 RCAP NDS Help Can someone help me out by posting an example (working example please!) of a NI2 RDB, NI2 DCH, and an example trunk that has NI2 as the IFC? I will be hooking up to a 5ESS switch and would like to configure this properly to get both ADD and NAME displays working. I've diligently studied the NTP's for guidance, but there are SO many options for RDB that my head is swimming. I have tried to take an existing DCH,Route, and Trunks and change them to NI2 with RCAP set to NDS, but you cant change them, you have to out and rebuild, but the settings are a little different. Can anyone assist me? Many Thanks, Wherewolf | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member ![]() westcoaster has no status.
Location: Canada! Rep Power: 6 ![]() | *option 11 system* TYPE RDB CUST 00 DMOD ROUT 30 DES NORTEL TKTP DID NPID_TBL_NUM 0 SAT NO RCLS EXT VTRK NO NODE DTRK YES BRIP NO DGTP PRI ISDN YES MODE PRA IFC NI2 CBCR NO NCOS 0 SBN NO PNI 00000 NCNA YES NCRD NO CHTY BCH CPFXS YES CPUB OFF DAPC YES TBL 1 BCOT 0 INTC NO DSEL VOD PTYP PRI AUTO NO DNIS NO DCDR NO ICOG IAO RANX NO SRCH LIN TRMB YES STEP ACOD 7222 TCPP NO PII NO TARG 01 CLEN 1 BILN NO OABS INST IDC YES DCNO 1 NDNO 1 * DEXT NO DNAM NO ICIS YES TIMR ICF 512 OGF 512 EOD 13952 NRD 10112 DDL 70 ODT 4096 RGV 640 FLH 510 GRD 896 PAGE 002 SFB 3 NBS 2048 NBL 4096 DRNG NO CDR NO MUS YES MRT 40 EQAR NO FRL 0 0 FRL 1 0 FRL 2 0 FRL 3 0 FRL 4 0 FRL 5 0 FRL 6 0 FRL 7 0 TTBL 0 ATAN NO PLEV 2 MCTS NO ALRM NO ART 0 SGRP 0 AACR NO ADAN DCH 10 CTYP TMDI CARD 01 PORT 1 DES COtrunk USR PRI DCHL 1 OTBF 32 PARM RS232 DTE DRAT 64KC CLOK EXT IFC NI2 ISDN_MCNT 300 CLID OPT0 CO_TYPE STD SIDE USR CNEG 1 RLS ID 1 RCAP COLP NDS MBGA NO OVLR NO OVLS NO T310 120 T200 3 T203 10 N200 3 N201 260 K 7 BSRV NO REQ: prt TYPE: did TN CDEN CUST DATE PAGE DES NORTEL TN 001 01 TYPE DID CDEN SD CUST 0 TRK PRI PDCA 1 PCML MU NCOS 0 RTMB 30 1 B-CHANNEL SIGNALING NITE STRI/STRO OWK OWK AST NO IAPG 0 CLS UNR DTN WTA LPR APN THFD HKD P10 VNL TKID AACR NO DATE 21 MAR 2006 DES PRI TN 001 02 TYPE DID CDEN SD CUST 0 TRK PRI PDCA 1 PCML MU NCOS 0 RTMB 30 2 B-CHANNEL SIGNALING NITE STRI/STRO OWK OWK AST NO IAPG 0 CLS UNR DTN WTA LPR APN THFD HKD P10 VNL TKID 5554101 AACR NO DATE 24 MAR 2006 Last edited by westcoaster; 04-26-2006 at 10:44 PM. | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Senior Member ![]() WhereWolf is sober (maybe....)
Rep Power: 4 ![]() | Thanks for the quick reply. I tried your settings and haven't got it to work yet.....I have a 61C, but I don't see much difference other than the type of DCH card. On the DCH setting you have the CO type set for Bellcore, where I'm attaching to a ATT 5ESS switch, I've tried both settings - same same. AARRGGGHHH! ADAN DCH 18 CTYP MSDL DNUM 11 PORT 0 DES INTPRI USR PRI DCHL 18 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT IFC NI2 ISDN_MCNT 300 CLID OPT0 CO_TYPE ATT SIDE USR CNEG 1 RLS ID 1 RCAP COLP NDS MBGA NO OVLR NO OVLS NO T310 120 T200 3 T203 10 N200 3 N201 260 K 7 BSRV NO TYPE RDB CUST 00 ROUT 6 DES PRI_DID TKTP DID NPID_TBL_NUM 0 SAT NO RCLS EXT VTRK NO DTRK YES BRIP NO DGTP PRI ISDN YES MODE PRA IFC NI2 CBCR NO NCOS 0 SBN NO PNI 00000 NCNA YES NCRD NO CHTY BCH CPFXS YES CPUB OFF DAPC NO BCOT 0 INTC NO DSEL 3VCE PTYP PRI AUTO NO DNIS NO DCDR NO ICOG IAO RANX NO SRCH LIN TRMB YES STEP ACOD 6722 TCPP NO PII YES TARG 01 02 03 04 05 CLEN 1 BILN NO OABS INST IDC YES DCNO 1 NDNO 1 * DEXT NO DNAM NO ICIS YES TIMR ICF 512 OGF 512 EOD 13952 NRD 10112 DDL 70 ODT 4096 RGV 640 FLH 510 GRD 896 SFB 3 NBS 2048 NBL 4096 IENB 5 VSS 0 VGD 6 DRNG NO CDR NO VRAT NO MUS YES MRT 3 EQAR NO FRL 0 0 FRL 1 0 FRL 2 0 FRL 3 0 FRL 4 0 FRL 5 0 FRL 6 0 FRL 7 0 OHQ NO OHQT 00 TDET NO TTBL 0 ATAN NO PLEV 2 MCTS NO ALRM NO ART 0 SGRP 0 AACR NO DES PRI4ID TN 018 01 TYPE DID CDEN SD CUST 0 TRK PRI PDCA 1 PCML MU NCOS 0 RTMB 6 47 B-CHANNEL SIGNALING NITE STRI/STRO OWK OWK AST NO IAPG 0 CLS UNR DTN WTA LPR APN THFD HKD P10 VNL TKID DATE 27 APR 2006 | ||||||||
| | |
| | #4 (permalink) | ||||||||
| Junior Member ![]() westcoaster has no status.
Location: Canada! Rep Power: 6 ![]() | Your service providor should have some kind of form that would give you the details on how your pri is programmed (from the CO) My (mis)understanding is the 5ESS and the ATT protocol would be used when connecting to a toll office. While your CO equipment may be 5ess I don't think you would use the ATT protocol. | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Senior Member ![]() WhereWolf is sober (maybe....)
Rep Power: 4 ![]() | Thanks to those that chimed in on this. I got it working over the weekend - the CO Type is ATT vs STD, and additional on the DCH BSRV is Yes - I don't know if that's why it now works, but I'm not complaining. I'll post up my settings for future reference when I get a chance. Thanks again! Wherewolf | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Assign RCAP CCBS | avayapbx | Meridian Systems | 1 | 11-11-2004 12:19 AM |
| RCAP in LD 16 | gei_spot | Meridian Systems | 3 | 12-23-2002 01:07 AM |
| RCAP in LD 16 | gei_spot | Meridian Systems | 7 | 12-19-2002 05:49 PM |