Old 04-19-2006, 09:09 AM   #1 (permalink)
Zapa
Junior Member
 
Zapa's Avatar
Zapa is back

Activity Longevity
3/20 9/20
Today Posts
0/0 sssssss47
Location: Madrid
Rep Power: 0Zapa is an unknown quantity at this point
Gender:
Country:
Send a message via MSN to Zapa
Question Creating new Errors

Hi anyone who read this...

I've been trying to add some keycodes on a 11C option, and, following the NTPs and my own criteria (), I started doing a LD 43 - EDD.

And here is where my headaches begins: the systems accepts the command, thinks (for about 10 seconds) and then: .EDD112 .
Ok, let see ERR EDD112. What? OVL441 Help text not found for error code: EDD112. Ok, ok... Don't panic! Let see NTP Sofware Input/Output:System Messages. No data?? Let search in the whole collection... Nothing? NADA??!! Ok. Now you can panic.

Help? please??
Zapa is offline   sendpm.gif Reply With Quote
Old 04-19-2006, 09:40 AM   #2 (permalink)
WhereWolf
Senior Member
 
WhereWolf's Avatar
WhereWolf is sober (maybe....)

Activity Longevity
11/20 13/20
Today Posts
0/0 ssssss475
Rep Power: 4WhereWolf is on a distinguished road
Gender:
Country:
error edd112 = security check failed. I looked this up in OTM. The online help doesn't list it.
I would guess there is something wrong in the keycode or the keycode doesn't match the system.

Hope this helps,

Wherewolf
WhereWolf is offline   sendpm.gif Reply With Quote
Old 04-19-2006, 10:25 AM   #3 (permalink)
Zapa
Junior Member
 
Zapa's Avatar
Zapa is back

Activity Longevity
3/20 9/20
Today Posts
0/0 sssssss47
Location: Madrid
Rep Power: 0Zapa is an unknown quantity at this point
Gender:
Country:
Send a message via MSN to Zapa
But I didn't changed the keycodes... and it was working...
Thanks for the error feedback, but, i'm almost at the beginning
Zapa is offline   sendpm.gif Reply With Quote
Old 04-20-2006, 03:10 AM   #4 (permalink)
TomasSouth
Junior Member
 
TomasSouth's Avatar
TomasSouth has no status.

Activity Longevity
3/20 20/20
Today Posts
0/0 ssssss295
Rep Power: 6TomasSouth is on a distinguished road
Send a message via MSN to TomasSouth
Quote:
Originally Posted by Zapa
Hi anyone who read this...

I've been trying to add some keycodes on a 11C option, and, following the NTPs and my own criteria (), I started doing a LD 43 - EDD.

Help? please??
You said you are adding keycodes, so you have new keycodes? Any error while doing this process?
TomasSouth is offline   sendpm.gif Reply With Quote
Old 04-20-2006, 03:20 AM   #5 (permalink)
Zapa
Junior Member
 
Zapa's Avatar
Zapa is back

Activity Longevity
3/20 9/20
Today Posts
0/0 sssssss47
Location: Madrid
Rep Power: 0Zapa is an unknown quantity at this point
Gender:
Country:
Send a message via MSN to Zapa
Nopes...
Before entering the keycodes (LD 143, upgrade, blah blah...), I tried to perform an EDD on LD43... And there the party get started
Zapa is offline   sendpm.gif Reply With Quote
Old 04-20-2006, 03:31 AM   #6 (permalink)
TomasSouth
Junior Member
 
TomasSouth's Avatar
TomasSouth has no status.

Activity Longevity
3/20 20/20
Today Posts
0/0 ssssss295
Rep Power: 6TomasSouth is on a distinguished road
Send a message via MSN to TomasSouth
Was everything still correct in LD 22 SLT (ISM & the three KEYCODES) against your keycode sheet? How about the TID & aux ID?

EDD112 means there is a mismatch on them.
TomasSouth is offline   sendpm.gif Reply With Quote
Old 04-21-2006, 08:07 AM   #7 (permalink)
Zapa
Junior Member
 
Zapa's Avatar
Zapa is back

Activity Longevity
3/20 9/20
Today Posts
0/0 sssssss47
Location: Madrid
Rep Power: 0Zapa is an unknown quantity at this point
Gender:
Country:
Send a message via MSN to Zapa
TomasSouth, I think you need more beer to understand what I'm trying to explain (probably it's me who needs it ).

I never introduced the keycodes, nor check the SLT.
First I tried to do an EDD, but failed with an unknown error (thanks WhereWolf). Later I executed an SLT but ALL ISM PARAMETERS WHERE 0!!!!

Now, all is over: last night I found some courage (that was the bottle said ) and made a SYSLOAD (you know: ld 143 xsl).
After that, PBX returned from its insanity and finally keycodes where introduced, validated and made fully functional.

Thanks everybody!!!

P.S.- TomasSouth: I hope you not to take at bad my joke. If so, please excuse me, I didn't want to.
Zapa is offline   sendpm.gif Reply With Quote
Old 04-21-2006, 03:00 PM   #8 (permalink)
RICK007
Junior Member

Activity Longevity
0/20 20/20
Today Posts
0/0 sssssss29
Rep Power: 6RICK007 is on a distinguished road
Reload the switch
RICK007 is offline   sendpm.gif Reply With Quote
Old 04-21-2006, 04:31 PM   #9 (permalink)
datadump
Junior Member
 
datadump's Avatar
datadump has no status.

Activity Longevity
1/20 12/20
Today Posts
0/0 ssssss380
Location: Vatican City
Rep Power: 4datadump is on a distinguished road
Gender:
Country:
It's the security dongle 95% of the time... Clean the contacts. Thats the easy one.
the other 5% of the time is a corrupt security file on the C: drive. If it happens again.
first clean the dongle contacts.
if the EDD112 continue reload the OS
datadump is offline   sendpm.gif Reply With Quote
Old 04-22-2006, 05:38 AM   #10 (permalink)
TomasSouth
Junior Member
 
TomasSouth's Avatar
TomasSouth has no status.

Activity Longevity
3/20 20/20
Today Posts
0/0 ssssss295
Rep Power: 6TomasSouth is on a distinguished road
Send a message via MSN to TomasSouth
Quote:
Originally Posted by Zapa
P.S.- TomasSouth: I hope you not to take at bad my joke. If so, please excuse me, I didn't want to.
That should not be a problem. I enjoy this forum. None of us knows everything, good thing a forum like this was created. Good thing for the starters.

See life during 1996 (year I begin with nortel pabx, still not perfect until now ), no forum, just NTPs beside you, and help with the seniors who were also cannot give much time on you.

TomasSouth is offline   sendpm.gif Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
XMI000 errors and crosstalk hoizy Meridian Systems 5 04-10-2006 06:45 PM
IFC ESS5 PRI232 Protocol Errors tbraddock Meridian Systems 1 07-28-2005 03:20 PM
Secondary HUNT causes MMail errors Buckshot Meridian Systems 3 06-01-2005 09:20 AM
If god were a PC programmer (long but funny) Pirates_Ghost Off Topic - Humor/Jokes 1 12-06-2004 09:25 AM
Carrier reporting CRC errors freddog Meridian Systems 10 06-26-2003 03:08 PM