Location: Houghton, NY Rep Power: 7 ![]() | We restarted our PBX today and had many boot up errors regarding LOOP 30/31. None of my loops or IPE shelfs came up on their own. I had to manually enll all loops and enxp all controllers. The slot for 30/31 in the CE shelf is empty, however we do have a supl card in 28/29. I checked CEQU and SUPL and 30 is not referenced. CEQU MPED 8D TERM REMO TERD REMD TERQ REMQ SUPL 004 008 012 028 N096 XCT 000 016 TDS * 000 * 016 CONF * 001 * 017 MFSD * 000 * 016 DLOP NUM DCH FRM LCMT YALM TRSH TRK 003 24 D3 AMI DG2 00 019 24 ESF B8S FDL 00 EXT0 3PE CNI 008 000 005 CNI 008 001 000 EXT1 3PE CNI 008 000 005 CNI 008 001 000 MCFN S0B0 S0B1 S1B0 S1B1 S2B0 S2B1 S3B0 S3B1 FLSH TOTL 016 016 016 016 000 000 000 000 64 128 SUPL SUPT SLOT XPEC0 XPEC1 004 STD LEFT 02 0 3 03 0 3 008 STD LEFT 01 0 3 -- - - 012 STD LEFT 04 0 3 07 0 3 028 STD LEFT 05 0 3 06 0 3 096 ---- ---- PHANTOM -- - - These are the error messages: BERR600 NCB 0 0: Check Device "LOOP 30" at address 0x8781 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 30" at address 0x8781 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 30" at address 0x8781 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 31" at address 0x87c1 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 31" at address 0x87c1 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 31" at address 0x87c1 in Group 0 Check IO device, network device, or PS card BERR704 EXC 0: Bus Error in ISR SR=0x2700, PC=0x501aed8, Addr=0x13021f04, SSW=0x1050020 BERR704 EXC 0: Bus Error in ISR SR=0x2700, PC=0x501aed8, Addr=0x13021f04, SSW=0x1050020 BERR600 NCB 0 0: Check Device "LOOP 31" at address 0x87c1 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 31" at address 0x87c1 in Group 0 Check IO device, network device, or PS card BERR600 NCB 0 0: Check Device "LOOP 31" at address 0x87c1 in Group 0 Check IO device, network device, or PS card SRPT789 RST 0: Exception-caused task restart: TID=0x8c5fd7c, vec=0x2, pc=0x41e7e 84 This system has been up and running since, however, I am still baffled about the loop 30/31. | ||||||||
| | |
| | #4 (permalink) | |||||||||
| Junior Member
Location: Houghton, NY Rep Power: 7 ![]() | Quote:
Super Loop 28 has been around for some time and I understand this covers four normal term loops 28/29/30/31, however I am unsure why the system would be complaining about Loop 30/31 when it is not configured and there is nothing in it's CE slot. Would a problem with the SUPL card in LOOP 28 cause this? Thanks for your replies. | |||||||||
| | |
| | #8 (permalink) | |||||||||
| Junior Member
Location: Calgary, Alberta Rep Power: 0 ![]() | Quote:
Is this an AC or DC 61C? Blair | |||||||||
| | |
| | #10 (permalink) | |||||||||
| Junior Member
Location: Houghton, NY Rep Power: 7 ![]() | We did a lot of testing today during the lunch hour. We did not have any of the odd issues with BERR errors on this restart which I am greatful for. We still have the problem with half our network equipment not coming up. All network loops on Shelf 1 came up fine (Loop 16-31). However, only the IGS, Per Sig, and TTYs on shelf 0 came up. All other loops remained disabled. I had to manually enable all loops on this shelf. During start up it seemed as if Supl 12 failed bringing it's controllers online. Failed firmware download according to the errors. We also had people state that they could not answer calls on the shelf. They would received dead air. I did the following troubleshooting. I downed Loop 28, two shelfs. Took the controllers from that loop and installed to Loop 12 (after taking down of course). I then turned on the shelfs and everything enabled on it's own. I then downed the shelf and started troubleshooting with mixed/matched XPEC controllers and it appears I may have a bad controller causing the loop not to auto enable. I have isolated one controller that I know is bad and will be ordering a replacement. I am thinking this may be what is causing Net shelf 0 (0-12) from coming up on it's own on a restart. I pasted my capture from the restart. Do see anything else that may point out why equipment in Net shelf 0 did not come up? Quote:
NOTES: Loop 18, 20, 21, 22 are new DTI/PRI not yet in use. The swith enabled them, however, failed daily routine because there is no carrier yet. | |||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| SCSI errors during MID routine??? | Rachelle | Meridian Systems | 6 | 07-08-2003 10:20 AM |
| Carrier reporting CRC errors | freddog | Meridian Systems | 10 | 06-26-2003 02:08 PM |
| Some errors... | ScottBye | Meridian Systems | 7 | 03-11-2003 02:28 PM |
| MSDL201 Errors | Tammie | Meridian Systems | 16 | 02-26-2003 11:50 AM |
| BUG 101 Errors | KLocke | Meridian Systems | 3 | 12-22-2002 01:43 PM |