| Hi, I have an option 61 working together with a SL1 but we want to get rid of the SL1. I want to migrate the SL1 extensions to an option 11. I connected the option 11 to the option 61 with a DTI2 card on each equipment. I programmed extensions on option 11. I create a CDP 41XX on O61 so I can direct the call to O11. When I dial from O61 an extension on O11 it works, the call is forwarded to the set on O11 and viceversa, but when I call from one equipmento to the other i can't see who's calling on the screen. How can I have the caller id working trought the equipments. I need the caller Id working because the VM system is on the O61. thank you | ||||||||
|
| | #4 (permalink) | ||||||||
| Guest
| Im not using a PRI im usin a regular DTI2 (E1) card and im not using R2 signaling, Do I have to use it? here is the RDB programing REQ: prt TYPE: rdb CUST 0 ROUT 13 TYPE RDB CUST 00 ROUT 13 DES 61-11 TKTP TIE ESN NO RPA NO CNVT NO SAT NO RCLS EXT DTRK YES DGTP DTI2 DSEL VOD PTYP DTT AUTO NO DNIS NO ICOG IAO SRCH RRB TRMB YES STEP ACOD 7014 TARG BILN NO OABS INST IDC NO DCNO 0 * NDNO 0 DEXT NO ANTK SIGO STD STYP SDAT MFC NO TIMR ICF 512 OGF 512 EOD 13952 DSI 34944 NRD 10112 DDL 70 ODT 4096 RGV 640 GTO 896 GTI 896 SFB 3 TFD 0 SST 5 0 DTD NO SCDT NO 2 DT NO NEDC ETH FEDC ETH CPDC NO DLTN NO HOLD 02 02 40 SEIZ 02 02 SVFL 02 02 DRNG NO CDR NO NATL YES SSL CFWR NO IDOP NO MUS NO PAGE 002 PANS YES MANO NO FRL 0 8 FRL 1 8 FRL 2 8 FRL 3 8 FRL 4 8 FRL 5 8 FRL 6 8 FRL 7 8 OHQ NO OHQT 00 CBQ NO AUTH NO TDET NO TTBL 0 OHTD NO PLEV 2 OPR NO ALRM NO ART 0 OPDL 0 PECL NO DCTI 0 NADT 0 FRIN NO RRBS NO RLSM 0 CCBA NO AACR NO | ||||||||
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| setting procomm for phonemail | gezekiel | Siemens / Rolm | 2 | 11-06-2003 08:56 PM |
| Option 11c Maintenance Terminal - Revisited | dppnwspec | Meridian Systems | 6 | 02-21-2003 02:27 PM |
| Option 11c tied to 61c | MrClean61 | Meridian Systems | 2 | 02-06-2003 02:52 PM |
| Purchasing an Option 11C How do you know? | morpheus | Meridian Systems | 18 | 12-20-2002 11:28 AM |
| DIG ringing option | switch | Meridian Systems | 3 | 12-17-2002 02:24 PM |