| Junior Member ![]()
Location: Houghton, NY Rep Power: 7 ![]() | When restarting my PBX only have of my networking equipement and IPE shelves come up on there own. I then have to manually enable loops and controllers for the remaining. When the system is restarted the software is loaded, the 3PE's, IGS, and TTYs in both my network shelves come up, however, only the loops in Network (CE) shelve 1 come up on it's one: Conf/TDS Loop 16/17 PRI Loop 19 SLOOP NET 28 All comes up on it's own. The system then does a data dump I have to manually enable all loops in Network (CE) Shelf 0: Conf/TDA Loop 0/1 PRI Loop 3 SLOOP NET 4 SLOOP NET 9 SLOOP NET 12 This is not a big deal for me to manually enable as I have the procedure completly documented, however, was wondering why the other shelf's loop come up on their and and this shelf's loops I have to enable manually. Thanks, Jes | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Junior Member ![]()
Location: Houghton, NY Rep Power: 7 ![]() | There is no red lights when the shelves are up, however, after a power cycled restart they are all red and then turn off as they come up. I have ran the SHLF command on all the shelfs and it states OK... Any other test you can refer me to? | ||||||||
| | |
| | #7 (permalink) | ||||||||
| Junior Member ![]()
Location: Canada Rep Power: 4 ![]() | check all your cable connectors , make sure all are latched properly. pay particular attention in the clock & igs cable routing. If everthing o.k. Then try to reboot again. If problem comes up, go to ld 39 stat all your igs and stat scg and try to swap the clock. Try to check the status of ps card in ld32 stat per x. Is this a new install or the existing system ? | ||||||||
| | |
| | #9 (permalink) | |||||||||
| Senior Member ![]() slagburn has no status.
Location: 3498.51 miles from Tiverton, Ontario (CANADA) Rep Power: 16 ![]() | Quote:
| |||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Gardening...( I fixed my car A/C here..What the heck) | Twisted | Meridian Systems | 9 | 05-22-2003 10:48 AM |
| External forwarding. | jimtpg | Meridian Systems | 32 | 01-13-2003 01:28 PM |
| For when you have a half hour or so and need a good laugh | gei_spot | Off Topic - Humor/Jokes | 1 | 01-06-2003 09:56 AM |