| |||||||||
![]() | | ||||||||
| |||||||||||||||
| |||||||||||||||
| Meridian Systems Welcome to the Nortel Meridian Forums Including Meridian Options 11-81C CS1000M Meridian Mail Call Pilot Companion and Sucession Hospitality OTM MAT MICB RAN NetGateway ..., and all other Applications |
| Tags: reset, serial, trouble |
![]() |
| | LinkBack | Thread Tools | Display Modes |
| | #1 (permalink) | ||||||||
| Guest
| BCM 3.6 Reporting for Call Centers and IIS 6 Have an option 61C nortel meridian pbx. It comes with 3 serial outputs, one for the voicemail, one for a console, and one we use for Optivity Telephony Manager (OTM) Problem: OTM says it cannot get OVL111 prompt from the switch. **** Is there any way I could reset the Serial line to normal status using a console command ----UPDATE----- Ive read more about this and its somewhere in the LD 17 overlay (i think), does anyone know the subcommands in this overlay (or where to find the documentation for it) | ||||||||
|
| | #2 (permalink) | ||||||||
| Senior Member ![]() slagburn has no status.
Location: 3498.51 miles from Tiverton, Ontario (CANADA) Rep Power: 16 ![]() | Re: (WARNING: Partisan sour grapes humor) Nixon v. Bush Administrtion of TTY ports through LD17 is covered on page 466 of document 553-3001-311 Meridian 1 Software Input/Output Guide Administration If nothing has changed in the programing of the TTY port then you might be more interested in the TTY maintenance load... LD37 page 199 of document 553-3001-511 Meridian 1 Software Input/Output Guide Maintenance If you don't have either of these you can download them from the Nortel website... see sticky at top of forum. Here are the LD37 commands... CDSP Clear the maintenance display on active CPU to 00 or blank CMIN Clear the minor lamp on a system basis CMIN ALL Clear minor alarm indication on all attendant consoles DIS MSG Disable incoming message monitoring for the primary PMSI port. DIS MSGO Disable outgoing message monitoring for the primary PMSI port. DIS MSI x Disable Mass Storage Interface card x (not valid on Option 11C) DIS PRT x Disable printer x DIS TTY x Disable TTY x. (valid only for Card 0 Port 0 TTY on Option 11C systems) END Clear all test activity ENL MSGI Enable incoming message monitoring for the primary PMSI port. ENL MSGO Enable outgoing message monitoring for the primary PMSI port. ENL MSI x Enable Mass Storage Interface x ENL PRT x Enable printer x ENL TTY x Enable TTY x MSI x Test Mass Storage unit x (not valid on Option 11C) MSI DATA Test data validity in primary and backup device. (not valid on Option 11C) MSI RW x Test READ/WRITE ability of Mass Storage unit x. (not valid on Option 11C) MSI SELF x Perform self-test on MSI card x and report result .(not valid on Option 11C) PRT x Test printer x SET MON 0 Set the monitoring display to be in alphanumeric format. This applies to the primary PMSI port. SET MON 1 Set the monitoring display to be in hexadecimal format. This applies to the primary PMSI port. STAT Provide status of all input/output devices in system STAT LINK Provide status of all CDR links STAT LINK x Provide status of CDR data link x STAT MON Get the monitoring status for the primary PMSI port. This command displays the status of the message monitoring for the primary port. For example, if MSGI, MSGO, and SET MON 0 are enabled, the display would be as follows. MSGI:ON MSGO: ON ALPH STAT MSI Provide status of all MSI cards STAT MSI x Provide status of MSI card x STAT PRT Provide status of all printers in system STAT PRT x Provide status of printer x STAT TTY Provide status of all TTY devices in system This command enables you to get the status of the primary PMSI I/O port, and the Single Terminal Access (STA) administration terminal. STAT TTY x Provide status of TTY x This command also provides the status of the primary PMSI port. STAT XSM Provide status of the system monitor TTY x Test TTY x | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Guest
| Thanks so much, that really helped. I looked through the otm logs and found that it was using tty5. I then ld37 and issued the command stat tty. I found out that for some reason the tty 5 was disabled. All i had to do to reenable it was ENL TTY 5 Now works fine. Is there any way the switch can disable the port on its own without issuing a command to disable it manually ? Thanks again | ||||||||
|
| | #7 (permalink) | |||||||||
| Senior Member ![]() slagburn has no status.
Location: 3498.51 miles from Tiverton, Ontario (CANADA) Rep Power: 16 ![]() | Quote:
| |||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Obtaining Serial No. of sets | jpaez_28 | Meridian Systems | 6 | 11-03-2003 09:48 PM |
| Nortel BCn Password reset | zedmike | Meridian Systems | 1 | 07-03-2003 11:31 AM |
| Serial # | ABabbitt | Meridian Systems | 2 | 06-23-2003 04:23 PM |
| Re: ATA Trouble (UPDATE) | Shooter | BCM and Norstar | 9 | 01-06-2003 09:39 AM |