Location: Lompoc, CA Rep Power: 6 ![]() | Forward DID back out on Route 1 I need help with installing a T1/PRI card. They system I have is an Axxess/Eclipse version 6. I have 3 nodes with four cabinets in each node networked with T1 card in the first cabinet of each node. These T1 cards were actually configured as E1s. I plan to install the T1/PRI for an ISDN circuit in the 2nd node card slot 23 as this is the only slot available. Will this work or will I experience problems with the card in the third cabinet? Also, will the T1s that are configured as E1s for the private network cause any problems with the PRI as far as the clocking of the PRI from the CO and the clocking of the private network E1s? Finally, under the reference clock list I have the 2 E1 cards listed as master to private network. Where in the list should I place the PRI as slave to public network or does it matter? Thanks for you help Tony | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member ![]()
Rep Power: 6 ![]() | VIDEO and VOIP E1/T1 cards need to go into the cabinets that your CPU cards are in and they also need to be as close as possible to the CPU cards, there should not be any station line cards in between so you may have to do some rearanging. The PRI will now provide your reference clock and should be the top entry and be the "slave to public network" | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| 10XX calls will not go through | 612moto | Meridian Systems | 74 | 08-08-2006 09:48 AM |
| NNC Alarm in TIE PRI | justzikle | Meridian Systems | 2 | 08-05-2006 03:31 AM |
| Mar. Mail 11 install tape needed! | travelingpcguy | Meridian Systems | 3 | 03-12-2004 09:46 AM |