Old November 4th, 2008   #11 (permalink)
Moderator
 
acejavelin's Avatar
acejavelin is a high-tech, heavy metal redneck!

Activity Longevity
11/20 5/20
Today Posts
0/0 ssssss622
Location: North Dakota
Rep Power: 2acejavelin is on a distinguished road
Gender:
Country:
Quote:
Originally Posted by socaljake View Post
I put the attached file (even used the one I posted here) on my lab VPU at v11 and all is good. The format is Rhetorex 24 bit.

I don't know what to say.

Just to recap. You recorded 6 seconds of nonsense to audiotex XXX, retrieved the real file system name zzz.r24, then renamed my file to match zzz.r24, right?
Yup, exactly 6 seconds. AVDAPMON showed the filename it created was e0.r24, there was also another file called e0.24, don't know if that is related or not, but we renamed the original e0.r24 file to e0.old.r24 (or something like that) then copied the ringback.r24 to the folder and renamed it e0.r24 and all we got was noise.

Will try this again later this week and let you know what happens.

Thanks again.
acejavelin is offline   sendpm.gif Reply With Quote
Old November 5th, 2008   #12 (permalink)
Moderator
 
acejavelin's Avatar
acejavelin is a high-tech, heavy metal redneck!

Activity Longevity
11/20 5/20
Today Posts
0/0 ssssss622
Location: North Dakota
Rep Power: 2acejavelin is on a distinguished road
Gender:
Country:
I did find the convert.exe tool that converts r24 files to WAV and back, tried it on your file and the audio was a clear ringback. Not wure what to try next, gonna play with it some and see what happens.

The convert.exe tool is attached if anyone is interested. It can be used to convert Inter-Tel VPU or AxxessoryTalk r24 audio files to WAV format and back.

It is command line based, just run the program and it will give you the command line format needed to run the program.
Attached Files
File Type: zip Rhetorex Audio Convert Utility.zip (33.0 KB, 115 views)
acejavelin is offline   sendpm.gif Reply With Quote
Old November 19th, 2008   #13 (permalink)
Moderator
 
acejavelin's Avatar
acejavelin is a high-tech, heavy metal redneck!

Activity Longevity
11/20 5/20
Today Posts
0/0 ssssss622
Location: North Dakota
Rep Power: 2acejavelin is on a distinguished road
Gender:
Country:
Well I finally got a chance to go back onsite and spent all day working on this one again.

I got the "ringback" greeting to work OK now. Not sure what happened before, but did it again and it worked fine, no noise, just a nice clean ringback.

The problem now is the VPU won't recognize the fax CNG tone, it just always routes it to the CRA's timeout destination. I have verified the fax board is installed correctly, swapped the two voiceboards around, reinstalled AVDAP several times, and spent 3 hours on the phone with tech support, and this time with someone who actually was helpful and didn't just tell me to "record fax tones" again. They are thinking we may have a bad Brooktrout fax board, but I still think it is a software issue. AVDAP monitor is not showing anything like "fax tone detection" and transferring the call the to fax board, so I don't think we are even getting to that stage yet.

Anyway, they fax board was new, so tech support is RMAing it and sending me a new one, we will see what happens.
acejavelin is offline   sendpm.gif Reply With Quote
Old November 19th, 2008   #14 (permalink)
Junior Member
 
socaljake's Avatar
socaljake is a new Dad!

Activity Longevity
0/20 5/20
Today Posts
0/0 sssssss22
Location: Scripps Ranch, CA
Rep Power: 0socaljake is a newbie
Gender:
Country:
I'm glad you got the ringback working! I only wish it solved all of you problems.

If AVDAP is setup correctly when a call hits the CRA you should see a line in AvdapMon reading "Fax Tone Detection Enabled". This should only display if you have the fax delivery email address programmed on that particular CRA. If it's not programmed the CRA will never listen for the fax and timeout.

Hope the MRA fixes it.
socaljake is offline   sendpm.gif Reply With Quote
Old December 19th, 2008   #15 (permalink)
Junior Member

Activity Longevity
0/20 6/20
Today Posts
0/0 sssssss23
Rep Power: 0umtech is a newbie
Country:
Quote:
Originally Posted by acejavelin View Post
Well I finally got a chance to go back onsite and spent all day working on this one again.

I got the "ringback" greeting to work OK now. Not sure what happened before, but did it again and it worked fine, no noise, just a nice clean ringback.

The problem now is the VPU won't recognize the fax CNG tone, it just always routes it to the CRA's timeout destination. I have verified the fax board is installed correctly, swapped the two voiceboards around, reinstalled AVDAP several times, and spent 3 hours on the phone with tech support, and this time with someone who actually was helpful and didn't just tell me to "record fax tones" again. They are thinking we may have a bad Brooktrout fax board, but I still think it is a software issue. AVDAP monitor is not showing anything like "fax tone detection" and transferring the call the to fax board, so I don't think we are even getting to that stage yet.

Anyway, they fax board was new, so tech support is RMAing it and sending me a new one, we will see what happens.
A few things, Does your summary.txt in the Avdap folder show you have fax ports? When you watch avdapmon does it show fax tone detection when the CRA answers the call. Either one of these could point to either software not loaded for the rhetorex board or no key on the back for the fax ports to be enabled. You do need to have a key on the machine to enable the fax ports.
umtech is offline   sendpm.gif Reply With Quote
Old December 19th, 2008   #16 (permalink)
Moderator
 
acejavelin's Avatar
acejavelin is a high-tech, heavy metal redneck!

Activity Longevity
11/20 5/20
Today Posts
0/0 ssssss622
Location: North Dakota
Rep Power: 2acejavelin is on a distinguished road
Gender:
Country:
Quote:
Originally Posted by umtech View Post
A few things, Does your summary.txt in the Avdap folder show you have fax ports? When you watch avdapmon does it show fax tone detection when the CRA answers the call. Either one of these could point to either software not loaded for the rhetorex board or no key on the back for the fax ports to be enabled. You do need to have a key on the machine to enable the fax ports.
Yes, the summary.txt file shows 2 fax ports and 12 voice ports. What we can nver get it to is show the "Fax Tone Detection Enabled" message in the avdap monitor no matter what we did.

This system does not have a hardware license key though, do you mean we need a special license as well? I am suprised that after several hours on the phone with tech support (over different days and with different techs) going over the Axxess system and the voicemail no one said anything. Can you confirm this for me?

Wish I had this information before, because the customer told us to pull the fax board and give up instead of sinking more money into labor hours to get this working... might have to bring this up again with them and see what they want to do.

Thanks.
acejavelin is offline   sendpm.gif Reply With Quote
Old December 19th, 2008   #17 (permalink)
Junior Member
 
socaljake's Avatar
socaljake is a new Dad!

Activity Longevity
0/20 5/20
Today Posts
0/0 sssssss22
Location: Scripps Ranch, CA
Rep Power: 0socaljake is a newbie
Gender:
Country:
Quote:
Originally Posted by acejavelin View Post
This system does not have a hardware license key though, do you mean we need a special license as well? I am suprised that after several hours on the phone with tech support (over different days and with different techs) going over the Axxess system and the voicemail no one said anything. Can you confirm this for me?
From the manual:

socaljake is offline   sendpm.gif Reply With Quote
Old December 19th, 2008   #18 (permalink)
Senior Member

Activity Longevity
0/20 4/20
Today Posts
0/0 ssssss102
Location: Long Beach, CA
Rep Power: 2wicksmagic is a newbie
Gender:
Country:
I'm pretty sure the license key is only for Unified Messaging. You do not need a license key for inbound faxing. Please correct me if I'm wrong.

One way I've always had success with the 1 DID programming to work is

-Create a CRA that times out to a respective extension.
-In the Day and Night greetings I put in 7 seconds of silence.
(One of our customers did not like the silence so we put a greeting in "You're calls may be recorded or monitored for quality assurance purposes")
-Then of course put the proper email address in Fax Delivery Email Adress

Just my two cents. Your method is very creative socaljake. I might look into that in the future.
Hopefully the new Brooktrout fax board solves all of your woes acejavelin. It sounds like you've been extremely thorough in your troubleshooting. Good Luck!
wicksmagic is offline   sendpm.gif Reply With Quote
Old May 19th, 2009   #19 (permalink)
Junior Member

Activity Longevity
0/20 3/20
Today Posts
0/0 ssssssss1
Rep Power: 0calipence is a newbie
Country:
Quote:
Originally Posted by acejavelin View Post
I did find the convert.exe tool that converts r24 files to WAV and back, tried it on your file and the audio was a clear ringback. Not wure what to try next, gonna play with it some and see what happens.

The convert.exe tool is attached if anyone is interested. It can be used to convert Inter-Tel VPU or AxxessoryTalk r24 audio files to WAV format and back.

It is command line based, just run the program and it will give you the command line format needed to run the program.
Did anyone ever find a GUI equivalent? When I use this converter, all I get is noise. Am I missing an option somewhere?
calipence is offline   sendpm.gif Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
DID Faxing MGO Inter-Tel 9 April 2nd, 2008 01:24 PM
DID Faxing ttosun Inter-Tel 7 January 30th, 2008 09:33 AM
DID Faxing infringer Comdial 3 December 17th, 2007 05:59 PM
Adding voicemail to Intertel Axxess system dwessell Inter-Tel 15 August 9th, 2007 01:42 PM
Faxing over PRI with BCM kennytlaloc BCM and Norstar 4 August 26th, 2003 05:15 PM


All times are GMT -4. The time now is 08:23 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.2.0
Copyright (c) www.pbxinfo.com - PBX Info | Free PBX, PABX, IP PBX, VOIP and Telephone Information Resource Forum - Avaya / Nortel, Cisco, Panasonic, Mitel, ShoreTel, more...