Location: Pittsfield, MA Rep Power: 6 ![]() | Help/Advice Needed on choosing small system I am trying to connect a fax server(RightFAX) to a HICOM using T-1 E&M. The Brooktrout board is a TR1034 24 channel. I am using the exact same programming as another fax server connected with a Brooktrout TR114 16 channel. I don't know if it is a PBX config problem or the server. Of course the server guys say it is the voice guy's problem. There is not any hardware options on the TR1034 to set up, so it is installed as shipped. I don't know what software options exist in the driver, or server software. The fax management for the server shows all channels idle, and the HICOM shows all channels ready. I get busy when calling the extension pointed to the server. and outgoing fax calls fail also. I have spent hours staring, and comparing the two Siemens configs, and they are identical. Any ideas anyone? | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Moderator ![]() bobmay has no status.
Location: Pittsfield, MA Rep Power: 6 ![]() | Here is my Siemens config M1: NO COMMAND ENTERED <dis-bcsu TYPE = tmd LTG = 1 LTU = 3 SLOT = 91 DIS-BCSU:TMD,1,3,91; H500: AMO BCSU STARTED --------------------------------------------------------------- | DETAILS OF TMD BOARD AT ADDRESS (LTG.LTU.SLOT) = 1. 3. 91 | | | | CABTYP = 3 TIMTYP = SYST SIGTYP = CAS | | FRAME = ESF TABS = NO FCTID = 1 | | BI8SUB = YES BIVDET = YES | |-------------------------------------------------------------| | RDRATIO = 6 RDTH = 2500 RDQUAL = 15000 | | YLSEND = 5000 YLTH = 400 YLQUAL = 100 | | LOS = 150 AOS = 4000 | | SESDISTH = 10 SESREQTH = 10 | | OESDISTH = 30 OESDISIN = 24-00-00 | | OESREQTH = 4 OESREQIN = 04-00-00 | |-------------------------------------------------------------| | NETUSR = ACKTIM = DLVTIM = | | OCTMAX = RETMAX = WINDOW = | | CRIDC = TTSC = NSFIV = | | NSFTSC = PFDGT = | |-------------------------------------------------------------| | IGN = IID = | --------------------------------------------------------------- AMO-BCSU -111 BOARD CONFIGURATION, SWITCHING UNIT DISPLAY COMPLETED; <dis-tgacc TGRP = 13 DIS-TGACC:13; H500: AMO TGACC STARTED +------------------------------------------------------------------------------+ | TGRP NUMBER : 13 TGRP NAME : DR RIGHTFAX /N MAXIMUM NO: 24 | | SUBGROUP NUMBER: 5 DEVICE TYPE: T1 E&M WINK DIR TYPE : BOTH | | ACD THRESHOLD : * TRACENO : 0 USAGE TYPE: TERR | | ALLOCATED TO AT LEAST ONE ROUTE GDTR RULE : 0 | | SELECTION : ROUND CFBLOCK : DISABLED | | THE FOLLOWING PORTS (LTG-LTU-SLOT-CIRCUIT) ARE ALLOCATED: | +------------------------------------------------------------------------------+ | 1- 3- 91- 1| 1- 3- 91- 2| 1- 3- 91- 3| 1- 3- 91- 4| 1- 3- 91- 5| 1- 3- 91- 6| +------------------------------------------------------------------------------+ | 1- 3- 91- 7| 1- 3- 91- 8| 1- 3- 91- 9| 1- 3- 91-10| 1- 3- 91-11| 1- 3- 91-12| +------------------------------------------------------------------------------+ | 1- 3- 91-13| 1- 3- 91-14| 1- 3- 91-15| 1- 3- 91-16| 1- 3- 91-17| 1- 3- 91-18| +------------------------------------------------------------------------------+ | 1- 3- 91-19| 1- 3- 91-20| 1- 3- 91-21| 1- 3- 91-22| 1- 3- 91-23| 1- 3- 91-24| +------------------------------------------------------------------------------+ AMO-TGACC-111 TRUNK GROUP ACCESS CODE DISPLAY COMPLETED; <dis-tcsu PEN1 = 1-3-91-1 PEN2 = 1-3-91-24 M40: APPLICABLE GROUP CONDITION: MAXIMUM OF 1 OUT OF 2 PARAMETERS DEV = SPECDEV = TYPE = DIS-TCSU:1-3-91-1,1-3-91-24,,,; H500: AMO TCSU STARTED +------------------------------------------------------------------------+ | PEN: 1- 3- 91- 1 INS: Y BOARD: TMDN64P DEV: T1EMW TGRP: 13 | +------------------------------------------------------------------------+ | TRKID : 0251 TCCID : DR RIGHTFAX | | CCT : DR RIGHT/0251 | | | | ACDATA : 0 DPLN : 0 PFDGT : | | ATNTYP : TIE EXPDG : 10 PTTBLIDX : * | | COPNO : 50 ITR : 0 REMANA : | | COSNO : 45 LCRCOSD : 1 RULEIDX : | | COTNO : 50 LCRCOSV : 8 TRTBL : DIDCR | | DITIDX : 0 LOCANA : CIDDGTS : NONE | | | | * = NOT APPLICABLE TO THIS BOARD TYPE | +------------------------------------------------------------------------+ AMO-TCSU -111 TRUNK CONFIGURATION, SWITCHING UNIT DISPLAY COMPLETED; <dis-lrout ROUTE = 18 DIS-LROUT:18; H500: AMO LROUT STARTED LCR ROUTE DEFINITION TABLE -------------------------- ------------------------------------------------------------------------- |ROUTENUM = 18 SCHED A = X AORT = INFORMATION | |ROUTEELE = 1 B = AUTH = 2 TRANS CAP = S3 | |BEARER = ONE C = ONHKQ = N TRKSIG = TIE | |BANDWTH = 1 D = OFFHKQ = N SCCID = | |TRUNKGRP = 13 E = ODRNUM = 1 SVCVCE = NON | |MASTGRP = 240 F = APLTYP = VFD SVCN-V = NON | |ROUTSERV = N G = FACNUM = | | H = | ------------------------------------------------------------------------- END OF LCR ROUTE DEFINITION TABLE DISPLAY AMO-LROUT-111 ROUTE DEFINITION DETERMINATION PACKAGE DISPLAY COMPLETED; <dis-dpln TYPE = dgts DGTS = 6864 DPLN = CPS = DAR = DIS-DPLN H500: AMO DPLN STARTED -------------------------------------------------------------------------- | DIGIT INTERPRETATION VALID FOR DIAL PLAN 0 | -------------------------------------------------------------------------- | | CALL PROGRESS STATE | DIGIT ANALYSIS| | | | DIRECTORY NUMBER| 1 11111 1111222| RESULT |RSVD | ROUTE| | |12345 67890 12345 6789012| (SKIP DIGIT) | | | -------------------------------------------------------------------------- | 6864 |.**** ***** ***.* ......*| STN | | 18 | -------------------------------------------------------------------------- AMO-DPLN -111 DIALING PLANS, FEATURE ACCESS CODES DISPLAY COMPLETED; <dis-bssu LTG = 1 LTU = 3 SLOT = 91 CCTNO = ; DIS-BSSU:1,3,91,; H500: AMO BSSU STARTED +================================================= =============================+ | 24 HOUR TOTAL STATISTICS FOR TMDN LTG.LTU.EBT : 1 .3 .91 +------------------------------------------------------------------------------+ | ESF 0 | | ES 0 FS 0 | | BES 0 OES 0 | | US 0 DS 0 | +------------------------------------------------------------------------------+ | LOOPBACK STATUS: | | | | LOCAL : CLEAR PAYLOAD : CLEAR | | REMOTE REQUEST : CLEAR | +------------------------------------------------------------------------------+ | | | ALARM STATUS : NO ERRORS(GREEN) | +------------------------------------------------------------------------------+ AMO-BSSU -111 BOARD SWITCH, SWITCHING UNIT DISPLAY COMPLETED; <dis-sdsu STATUS = all LINK = TYPE = pen LEVEL = per3 LTG = 1 LTU = 3 SLOT = 91 CCT = ; DIS-SDSU:ALL,,PEN,PER3,1,3,91,; H500: AMO SDSU STARTED LTG1 (PERIPHERY) ------ MOUNTING LOCATION MODULE NAME NOM. BD(#=ACT) STATUS ------------------ LTG 1 --------------------- READY ------------------ LTU 3 --------------------- READY ** .LTG 1.LTU 3. 91 TMDN64P Q2484-X READY CCT LINE STNO SI BUS TYPE 1 3424 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 2 3425 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 3 3426 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 4 3427 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 5 3428 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 6 3429 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 7 3430 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 8 3431 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 9 3432 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 10 3433 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 11 3434 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 12 3435 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 13 3436 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 14 3437 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 15 3438 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 16 3439 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 17 3440 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 18 3441 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 19 3442 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 20 3443 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 21 3444 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 22 3445 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 23 3446 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 24 3447 READY ELEM DEV. . . . . . TMA CONN READY/CP CCT LINE STNO SI BUS TYPE 25 3448 READY AMO-SDSU -111 STATUS DISPLAY IN SWITCHING UNIT DISPLAY COMPLETED; < | ||||||||
| | |
| | #4 (permalink) | ||||||||
| Moderator ![]() bobmay has no status.
Location: Pittsfield, MA Rep Power: 6 ![]() | Found a good review of Cisco's IP Solution: We fixed this problem today. It was the server settings not the PBX config. Server had to be set to "do not detect loop current". Voice 1 Server dudes 0 | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Siemens HiCom 300 H - Cisco Call Manager Integration | sherlockphones | Cisco | 6 | 08-17-2008 09:56 PM |
| Hicom 300, CM-Win | nbiddle | Hicom/HiPath | 1 | 09-28-2006 08:12 AM |
| hicom 300 manuals | gyaneshwarmishra | Hicom/HiPath | 1 | 09-19-2006 02:10 AM |
| Siemens Hicom 300 system | eSmith | Hicom/HiPath | 1 | 09-03-2006 10:23 PM |
| Hicom 300 E Set up QSIG to Nortel M1 with Call Pilot | webstergl | Hicom/HiPath | 0 | 08-02-2006 03:10 PM |