| | #11 (permalink) | ||||||||
| Junior Member
Location: Preston, Lancs Rep Power: 0 ![]() | DTU Many thanks - just searched in and found this fixed same problem for me - Siemens engineer had batched a load of diverts and needed to change one - deleted it no problem but creating by stepping through add-actda gave same error (cannot mix fixed and variable forwarding). Using your command worked fine but didn't understand quite why. I am guessing by my system generated command line the VCE option counts as variable. | ||||||||
| | |
| | #13 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | To automaiticall forward a phone you can use the AMO CRON. this can be used to automatically at a given time/date and occurance to execute for example one taken on our system. ADD-CRON:POS=16,EXEC=P,MINUTE=30,HOUR=13,DAY=*,MONTH=* ,WEEKDAY=*,COMMAND="ADD-ACTDA:STN,1216,FWD,,1465;"; Cheers Clay | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Siemens HiCom 300 H - Cisco Call Manager Integration | sherlockphones | Cisco | 6 | 08-17-2008 09:56 PM |
| Hicom 300, CM-Win | nbiddle | Hicom/HiPath | 1 | 09-28-2006 08:12 AM |
| hicom 300 manuals | gyaneshwarmishra | Hicom/HiPath | 1 | 09-19-2006 02:10 AM |
| Siemens Hicom 300 system | eSmith | Hicom/HiPath | 1 | 09-03-2006 10:23 PM |
| Hicom 300 E Set up QSIG to Nortel M1 with Call Pilot | webstergl | Hicom/HiPath | 0 | 08-02-2006 03:10 PM |