Hipath 3550 QSIG networking over BRI

I have an issue with a number of Siemens Hipath 3550s which are connected to our global private network using Basic rate ISDN. Calls are routed to an Ericsson AXE10 at the core of the network however they connect directly at each site into a BRI interface on a Cisco 2800 series router (Cisco VIC2/2BRI/NT/TE) and the wide area traffic is converted to IP for part of the route. The AXE10 is configured to work either with ISO QSIG or ECMA (v2) QSIG and we already have a large number of sites working correctly using this protocol over a PRI interface.

The Hipath appears to be working at first however as soon as a user mis-dials a call (for example not completing a dial string or taking too long) then this locks out the BRI trunks. The typical way of resetting this is to re-seat the cables whereupon the trunks come back into service however obviously this is not sustainable in the long term.

We were first instructed by Siemens to install a clocking card which we did however this has not fixed the issue.

Any suggestions?

abm
abm is offline   sendpm.gif Reply With Quote
Old April 14th, 2009   #2 (permalink)
Junior Member

Activity Longevity
0/20 3/20
Today Posts
0/0 ssssssss4
Location: Australia N,S,W Mid North Coast
Rep Power: 0Alfred is a newbie
Gender:
Country:
Did you ever find a solution?
If not, I have a look at work as we have quite a number of those PABX's running on basic rate. (We call them OnRam over here).
Alfred is offline   sendpm.gif Reply With Quote
Reply


Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Hipath 3550 pin out request matthewsturt Siemens 2 June 3rd, 2009 12:19 PM
Help Please! Hipath 3550 Install Bill Lumbergh Hicom/HiPath 13 March 1st, 2009 03:19 AM
Hipath 3550 vpn interconnection john nichols Hicom/HiPath 6 September 9th, 2008 11:44 PM
siemens hipath 3550 ramjimh Hicom/HiPath 1 July 19th, 2007 03:42 PM
Hipath 3550 voice over IP smart Hicom/HiPath 2 July 13th, 2007 11:13 AM


All times are GMT -4. The time now is 12:35 AM.


Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.2.0
Copyright (c) www.pbxinfo.com - PBX Info | Free PBX, PABX, IP PBX, VOIP and Telephone Information Resource Forum - Avaya / Nortel, Cisco, Panasonic, Mitel, ShoreTel, more...