mr

I have a problem with an E1 connexion between HIPATH 4500 PBX and ERICSSON GSM MSC the E1 interface used on pabx is DIUN2 ISDN Q2196 but I use crc4 protocol on ericsson GSM MSC. Can some one help me? I want to know if DIUN2 ISDN use CRC4 protocol if non witch card can I use dont forget that PBX is HIPATH 4500

thanks
johnonyx is offline   sendpm.gif Reply With Quote
Old 07-03-2008, 02:38 AM   #2 (permalink)
Rajesharnair
Junior Member

Activity Longevity
4/20 2/20
Today Posts
0/0 sssssss53
Location: Bahrain
Rep Power: 0Rajesharnair is an unknown quantity at this point
Gender:
Country:
Send a message via Yahoo to Rajesharnair
I have carried out the networking between Siemens 4500 (DIUN2) and Ericsson MD110 (TLU76) using standard protocol s2conn. Keeping ericsson as master and siemens as slave.. Its working fine till to date.
Rajesharnair is offline   sendpm.gif Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


All times are GMT -5. The time now is 03:15 PM.

Tags   |   Advertise    |    Media Partners   |    Admin   |   About us   |   Contact Us   |   RSS   

Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.0.0
Copyright PBXINFO LLC 2006