| Junior Member
Rep Power: 0 ![]() | Good day Everyone! Did anybody have Hipath 4000 & Hicom 300 diun2 configuration file or any example cogfiguration of Diun2 board between Hipath4000 and Hicom 300. I already configured 2Mb line between two Hipath 4000 and three Hicom 300 but tranzit dialing in not working properly. Can anybody help me to solve this problem. thank you. | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | i've a question before solve your problem. What is the protocol that you use to connect hipath & hicom cornet o ecma? the protocol must have the same. After this you must change lwpar one have to be set master and other slave. try to set cop & cot in tdcsu. | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | I use cornet protocol! now i can call from one station to another, but transit call not working for example (it`s impossible to call from station A to station C through station B) i think the problem is in setting in LODR and LDPLN but i can`t understand parametrs of LODR and LDPLN. Also if yoy want i can send you by e-mail configuration for this 2-3(regen files) station. | ||||||||
| | |
| | #4 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | now i understand, so if you use a closed numeber (every stno number is unique in all the net) you must set in pbx b the stno number of pbx c with node number of pbx c: cha-wabe:stno,node number; if you want you can send me regen at alessandro.vignoli.ext@siemens.com | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| How to trace on Hipath 4000? | wreich | Meridian Systems | 2 | 07-13-2008 06:35 AM |
| payphones on the hipath 4000 | pbxcrn | Hicom/HiPath | 4 | 04-21-2008 06:19 AM |
| Hipath-4000 | rajithsekhar | Hicom/HiPath | 1 | 04-21-2008 06:14 AM |
| Comparison of MD 110 and Hipath 4000 | bhavik | Technology Chat | 3 | 10-27-2006 03:35 PM |
| IPDA for the HiPath 4000 | icetea | Hicom/HiPath | 0 | 05-13-2005 01:41 PM |