| | #1 (permalink) | ||||||||
| Guest
| Setting up phones in a Reception area I'm running a R5.1 Intuity with an S8700. Linked via IP trunks running H.323 are 4 IP Offices that are enabled for Audix voicemail. The problem is that, while there is integration for the IP Offices (call and terminate in correct mailbox, hearing subscriber greeting), message waiting lamps do not light. So what am I missing? In the intuity, I've assigned each subscriber the switch numbers indicated in the S8700, using the following settings from the PBX: disp isdn mwi = routing digits for machines 2, 4, 5, 6 set to aar routing code 8 plus 3-digit routing code (machine 2 --> routing digits 8201) li aar ana = routing code from above with min/max 7, route pattern matches routing code, call type lev0 (201, min/max 7, rt 201, lev0) li route = sends call to correct trunk, FRL 0, TSC=y, TSC Request=as-needed (group #101, FRL0, delete 3 digits, TSC=Y, TSCReq = as-needed) Anyone have any ideas? Thanks! Kristiana | ||||||||
|
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| > Words of wisdom from the BBC Comedy 'The Office'. | bash | Off Topic - Humor/Jokes | 27 | 04-07-2006 02:25 PM |
| Virtual Office | esemay | Meridian Systems | 6 | 10-10-2003 04:57 PM |
| Definity G3 & Intuity Remote Terminal Access | KMartin | Messaging | 3 | 01-08-2003 01:01 PM |