Rep Power: 0 ![]() | Restart Bp250 high, can someone help me For resolve the problem of Restart In BP 250. feauture used : OWS , CIL , MOH in MFU , CAS TRUNK the systeme was in R15 R3A, we had changed the CPU three Times and upgrade it 3times but we have the same Problem do you have any explication of the alarms enclosed 10 AC BATTERY BACKED UP RAM USAGE ERROR. 0400 02E8 FE SYS_INIT 11 DC PROTECTION LEVEL CHANGED. 3C00 9C8D 99 ST.OMINP 12 DB FEATURE PROTECTED BY FECU. BD19 B5BE BD ST.MUBEG 13 DB FEATURE PROTECTED BY FECU. BD19 B5BE BD ST.MUBEG 14 DB FEATURE PROTECTED BY FECU. BD19 B5BE BD ST.MUBEG 15 DB FEATURE PROTECTED BY FECU. BD19 B5BE BD ST.MUBEG 16 DC PROTECTION LEVEL CHANGED. 003C 9C8D 99 ST.OMINP 17 10 SYSTEM RESTART. BEA1 0000 FE SYS_INIT | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Junior Member ![]()
Rep Power: 0 ![]() | Alarm 10 pointing to BBRAM problem where all SPD data is stored...if CPU has been changed 3 times allready (changed whole CPU with BBRAM module not only CPU board and keep BBRAM module from old CPU!) it's more like firmware issue...try to upgrade firmware on all cards, including CPU (latest for CPU firmware is R1J and R15 R7A) Other alarms pointing to license usage...please check license for R15...if you changed CPU and keep original flash disk, you have to repair license on Ericsson web site. Also, be sure that CIL PC is connected and collecting CIL data...BP can restart if CIL data overflow to protected area (buffer reach his limit of 500 lines)... Regards | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Junior Member
Rep Power: 0 ![]() | thanks first we changed the CPU by a new one including his own BBRAM an Flash last Week we Replaced it by a new CPU R16 but the same Problems Appears and we had the same Alarmes 10 SYSTEM RESTART. BEA1 0000 FE SYS_INIT Can somme explain it to me the meaning of BEA1or give the alarm caused by CIL PC who make the BP250 Restart to compare it to this alarm Best Regards | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| restart/reboot/whatever | rodrigo_in_Brasil | Meridian Systems | 3 | 03-13-2008 04:22 AM |
| Pbx restart | moxxxa | Hicom/HiPath | 4 | 05-15-2007 03:27 AM |
| OS Restart | norstarrr | Meridian Systems | 3 | 03-06-2007 08:03 AM |
| restart command | ymbet | Meridian Systems | 3 | 03-20-2006 01:34 PM |
| Symposium Restart Required? | Contact Center Symposium and ACD | 2 | 12-29-2005 11:15 AM | |