| | #1 (permalink) | ||||||||
| Admin ![]() Chas2002 is scared by papa-bear\'s "not work safe"
Location: Gulf Coast Rep Power: 5 ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Cable Installation Procedures Hi All, Tomorrow I'm doing a survey of a Norstar (not sure what type) in one of our offsite warehouses. Currenly a T1 runs to the system, but there are only (3) stations. Use to be a lot of stations, but one group moved out. My mission - to find out if the T1 can be removed and replaced with (3) centrex lines.. What card would I need to look for to support Analog trunks? Thanks, Chas2002 | ||||||||
| | |
| | #2 (permalink) | ||||||||
| Senior Member ![]() Ramjet is wore ass out from the holidays!
Rep Power: 8 ![]() | Chas, you will need an LS/DS if you just want analog lines, or a CI if you want CLID. Basic if you are going in with plexar/centrex you just need to go to system programming and change the link timing to match your centrex hook flash. Post back if more help needed. | ||||||||
| | |
| | #3 (permalink) | ||||||||
| Admin ![]() Chas2002 is scared by papa-bear\'s "not work safe"
Location: Gulf Coast Rep Power: 5 ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | MerMail directions menu Thanks Ram - I'll take a digital picture. I'm gonna need all the help I can get - the last Norstar I worked on was a DR 5? (is that right) back in 1995.. Chas | ||||||||
| | |
| | #5 (permalink) | ||||||||
| Admin ![]() Chas2002 is scared by papa-bear\'s "not work safe"
Location: Gulf Coast Rep Power: 5 ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Ram - Do you know of or have you heard from Modley1 on the board? We are doing an "about us" file and Modley1 was our 'Norstar' rep and moderator. Would you be willing to fill in....We(I) haven't heard from him in quite a while... PM me or charlescarter@pbxinfo.com And I'll be in touch with all kinds of questions about this Norstar system.... Thanks, Chas2002 | ||||||||
| | |
| | #6 (permalink) | ||||||||
| Admin ![]() Chas2002 is scared by papa-bear\'s "not work safe"
Location: Gulf Coast Rep Power: 5 ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Remote terminal into OPTION 11 using symantec procomm RAM - Here are the digital pictures of the system. Currenlty there is a Mega-link from the CO to the system. We would like to remove that and replace it with regular analog lines. Looking at the system, cards installed, etc. - What would I need to get this up and running? Thanks, Chas2002 | ||||||||
| | |
| | #7 (permalink) | ||||||||
| Senior Member ![]() Ramjet is wore ass out from the holidays!
Rep Power: 8 ![]() | Nursing Home for all you phone techs that will be retiring.. Chas, I am at Dallas at Global Knowledge. Looking at your pics (limited computer access) it looks like a digital card in slot 1. I can't tell for sure, but do you also have a trunk mod? Replace the digital card with LS/DS cards and the same in the trunk mod if it is also a digital. In hardware settings, change from t1 to loop. What is a mega-link? Is it a t1 or pri. I will check back during breaks. | ||||||||
| | |
| | #9 (permalink) | ||||||||
| Admin ![]() Chas2002 is scared by papa-bear\'s "not work safe"
Location: Gulf Coast Rep Power: 5 ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | RAM - Pic 4 is the CO block. I haven't worked on a Norstar in a long time and I don't have any NTP's for the system. I will need to install (4) analog lines with a 1 to 1 match (CO 1 = Line 1, etc), and an independent fax number. Pic 5 shows the main housing: 1. Norstar Plus ICS 2. NT7B72FK - 0x32 T1 SFTWRE 3. NTB74GA - T1 PRI Card I guess I will need to pull that T1 Card and replace it with a Analog card. Do I have to do anything with Item 2? Thanks, Chas2002 | ||||||||
| | |
| | #10 (permalink) | ||||||||
| Junior Member ![]() ![]()
Rep Power: 5 ![]() | Since you have a spare slot (marked slot 3 on the KSU), all you need to do is install one LS/DS or CLID card (CLID will support caller-id). Your lines will be from Line025~Line028. You can leave the T-1 card installed and not have to worry about it. Since your software is MICS 3.0, the existing T-1 card will not support PRI (just an FYI software must be at 4.0 or higher to support PRI). Once installed, program the lines to Appear&Ring accordingly. You can change the line names to Line 1, Line 2, etc. to facilitate the Line 1 > CO 1 requirement. Since this system uses "soft programming" it doesn't matter where the lines physically terminate into the system as they can be programmed to any line button on any amount of phones. Your termination points on the System C.O. cable (3rd amphenol on KSU) will be as follows: Cable Pair / Physical Line / System Port Red-Brown / Line025 / 225 Red-Slate / Line026 / 226 Black-Green / Line027 / 227 Black-Brown / Line028 / 228 Since there more than likely was not a card previously installed in this slot, it should default to LOOP. If your lines don't work, check the HARDWARE configuration and insure Module 2, Card 2 is set for LOOP. The above information should get you going on your way. I will check back in a couple of hours to see if you have any further questions. Brewsky | ||||||||
| | |
![]() |
| Currently Active Users Viewing This Thread: 1 (0 members and 1 guests) | |
| Thread Tools | |
| Display Modes | |
| |
Similar Threads | ||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| 11c and PCMCIA Card | MJPearson | Meridian Systems | 22 | 06-26-2006 10:01 PM |
| DID card bad? | bkieler | BCM and Norstar | 4 | 11-19-2003 07:39 PM |
| Replace analog line card | thephoneguy | Meridian Systems | 2 | 08-04-2003 11:42 AM |
| Opt 11 slot map | freddog | Meridian Systems | 5 | 06-27-2003 11:00 PM |