Old 01-03-2006, 03:00 PM   #1 (permalink)
Techguy74
Junior Member
 
Techguy74's Avatar
Techguy74 has no status.

Activity Longevity
0/20 13/20
Today Posts
0/0 sssssss44
Location: Toronto
Rep Power: 4Techguy74 is on a distinguished road
Gender:
Country:
Send a message via MSN to Techguy74
I have a customer with a MICS XC3.0 that keeps getting Alarm code 51-02
The customer would find this on the alarm set often in the morning, and also the system would re-set during business hours.

Alarm 51 -A Trunk Module has been disconnected. Record the code displayed on the alarm telephone. Identify the module that caused the alarm. Power down the system. Check all connections to the Trunk Module. If the problem persists, replace the cables.

I swapped the CI cards from a trunk module...problem continued
Installed a new 0X32 keeping the MICS XC3.0 using NRU 11...probem continues....

Any ideas...I could replace the Software and hand-bomb the switch..but there's like 100 + sets

Any input would be much appreciated !

Toronto, Ontario
Techguy74 is offline   sendpm.gif Reply With Quote
Old 01-06-2006, 10:39 AM   #2 (permalink)
Shooter
Junior Member
 
Shooter's Avatar
Shooter has no status.

Activity Longevity
0/20 20/20
Today Posts
0/0 ssssss324
Location: Lake Elmo, Mn
Rep Power: 7Shooter is on a distinguished road
Country:
THIS SOUNDS LIKE YOU MAY BE HAVING A MODULE OR FIBER CONNECTION TO THE MODULE PROBLEM-
Shooter is offline   sendpm.gif Reply With Quote
Old 01-09-2006, 03:36 PM   #3 (permalink)
Techguy74
Junior Member
 
Techguy74's Avatar
Techguy74 has no status.

Activity Longevity
0/20 13/20
Today Posts
0/0 sssssss44
Location: Toronto
Rep Power: 4Techguy74 is on a distinguished road
Gender:
Country:
Send a message via MSN to Techguy74
Would 51-02 not mean it is Module 2 being the main cabinet ??

Do you think it could be a problem with the 6 port Fiber expansion ?
Techguy74 is offline   sendpm.gif Reply With Quote
Old 01-10-2006, 08:46 AM   #4 (permalink)
gogoGophers
Junior Member
 
gogoGophers's Avatar
gogoGophers is wishing he either didn\'t like pro football or was not a Lions fan

Activity Longevity
1/20 16/20
Today Posts
0/0 ssssss660
Location: Meechigan
Rep Power: 5gogoGophers is on a distinguished road
Gender:
Country:
I recently had a very similar situation, and after replacing all cards in the KSU (including 2 6 port fiber combo cards) and working with tech support for 2 days, the answer was - reinitialize programming. I did not want to do this. This may vary from your situation but I'll pass along what I did anyway. The system was spontaneously rebooting. In the KSU was a DTI card (for PRI), a 4 port LS/DS and 2, 6 port fiber exp, combo cards. In addition, they were having some very strange things happening with incoming calls on the PRI (to long to go into). I went into hardware, disabled module 2, changed the card type from PRI to T1, reenabled the module, disabled the module, changed it back to PRI, reenabled the module. This process clears out some line and routing information. I haven't had a restart since (3 weeks). I don't know if you can do something similar with the CI cards (change them in hardware to something else, then back again), but before you reinitialize, it might be worth a try.
gogoGophers is offline   sendpm.gif Reply With Quote
Old 01-10-2006, 09:15 AM   #5 (permalink)
Ramjet
Senior Member
 
Ramjet's Avatar
Ramjet is wore ass out from the holidays!

Activity Longevity
10/20 20/20
Today Posts
0/0 sssss1424
Rep Power: 8Ramjet is on a distinguished road
Gender:
Country:
Fishing For Job Ideas

Gophers, I too had the same trouble with a PRI and did the same thing. The switch has been quiet ever since. It very well might clear the trouble in the CI cards as well.
__________________
Two snips, a snort, a turn, a fly, and a grunt, and it was so simple, like the jitterbug, it plum evaded me!
Ramjet is offline   sendpm.gif Reply With Quote
Old 01-11-2006, 11:25 AM   #6 (permalink)
Techguy74
Junior Member
 
Techguy74's Avatar
Techguy74 has no status.

Activity Longevity
0/20 13/20
Today Posts
0/0 sssssss44
Location: Toronto
Rep Power: 4Techguy74 is on a distinguished road
Gender:
Country:
Send a message via MSN to Techguy74
That sounds good....I will give that a try and I will update you folks...

Thanks for the suggestions !

Toronto
Techguy74 is offline   sendpm.gif Reply With Quote
Reply



Currently Active Users Viewing This Thread: 1 (0 members and 1 guests)
 
Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
SPRE codes ycoder Meridian Systems 11 12-11-2006 01:29 AM
Help with LD 86, LD 87 and LD 90 sampicolo Meridian Systems 8 06-24-2003 09:06 AM
Alarm installer needs links. ukulele Technology Chat 2 06-18-2003 01:01 PM
Calling Line ID markj39k Meridian Systems 3 06-12-2003 06:12 AM
FFC's not working switch Meridian Systems 4 04-17-2003 08:51 AM


All times are GMT -5. The time now is 10:41 AM.

Tags   |   Advertise    |    Media Partners   |    Admin   |   About us   |   Contact Us   |   RSS   

Powered by vBulletin® Version 3.7.3
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.0.0
Copyright PBXINFO LLC 2006