http://www142.nortelnetworks.com/bvd...x/P0942453.pdf Page 478 of 1084
553-3001-311 Standard 9.00 January 2002
REQ CHG Request
TYPE PWD Change Password options
- PWD2 x...x Password 2
- LNAME_OPTION (NO) YES Require Log In Name for password access
- NPW1 x...x New Password 1 (PWD1 Log In password)
- - LOGIN_NAME aaa Log In Name for password access
- NPW2 x...x New Password 2 (PWD2)
- - LOGIN_NAME aaa Log In Name for password access
- LOUT 1-(20) Logout
- LAPW 0-99 Limited Access to Overlays Password number
- PWTP aaaa Password Access Type (aaaa = (OVLY) or SBA)
- - PWnn x...x Password (you may enter new password for SBA)
- LOGIN_NAME aaa Log In Name for password access
- LEVL aaaa Access Level for Set Based Administration password
(aaaa = (INST) or ADMN)
- - OVLA xx xx ... xx Overlays Allowed
- - CUST aaa Customer to be accessible by way of PWnn
- - TEN aaa Tenant to be accessible by way of PWnn
- - HOST (NO) YES Enable HOST mode Log In for password PWnn
- - MAT (NO) YES Enable MAT Log In for password PWnn
- - - MAT_READ_ONLY
(NO) YES Restrict MAT write access for password PWnn
- - OPT a...a Options for password PWnn (OPT responses can be found
on page 51

Gate Opener: VAS (Value Added Server) Page 479 of 1082
LD 17
- LPWD x...x Limited Access to Overlays log on password to be changed
- - NLPW x...x New Limited Access to Overlay Log On Password for the
user
- FLTH 0-(3)-7 Failed Log In Threshold
- LOCK 0-(60)-270 Lockout time
- FLTA (NO) YES Failed Log In Threshold Alarm
- AUDT (NO) YES Audit Trail for password usage
- - SIZE (50)-1500 Word Size of Audit Trail buffer
- LLID (NO) YES Last Log In Identification
- INIT (YES) NO Initialize to reset locked-out ports