| To create a phantom DN, you first create a phantom loop, and then define a TN within that loop. The system knows that any TN defined within that loop is a phantom TN. 1. check phantom loops, LD 97 REQ prt TYPE supl If no phantom loops are configured, REQ CHG TYPE SUPL SUPL Nxxx Prefix the loop number with N to create a phantom loop. The loop number range is 0–156 on Option 51C/61C/81C. On Option 81/ 81C, the loop range is 0–252 on Release 25 or later. On the Option 11C on X11 Release 23.55, the phantom loop number range is 64–80 in multiples of 4 (corresponds to slots 41–60). On the Option 11C on X11 Release 24 or higher, the range is 96–112 in multiples of 4 (corresponds to slots 61–80). |