Symposium 4.0 - creating DSN connection

this is a copy engineering bulliten
__________________________________________________ ____________________
SCCS GCCS Engineering Support Bulletin #17
__________________________________________________ ____________________

Title : Keycode Change to Reflect New M1 Serial Number (for Rls. 4)

PRS# : TM04130

Zip File : sccs0017.zip

Author : Angela Ho Oct. 30, 2000

Background:

The keycode is used to configure options and parameters
on the SCCS server. Input to generate the keycode include
M1 Serial Number, Meridian Link Server, Call Center Manager,
Host Enhanced Routing, Host Voice Processing, Script Data
Enhanced API, Realtime Basic Status API, Advance Script
Commands, Broadcast Announcements, Call Detail Reporting,
Maximum Positions, Maximum Active Client Sessions, Network
Control Center and Networking.


Problems / Symptoms:

A new SCCS server installation is required with a new keycode
to just change the M1 serial number (no added feature or
capacity expansion). This is a tedious procedure for sites.
This can happen if the site mistakenly order a keycode with
the M1 serial number that does not match that of the switch.


Systems
Affected :

All SCCS Systems. This utility is only applicable with SCCS
Release 4 (ie. NGEN Release 4)


Solution :

Note that this procedure will only allow a M1 serial number
change with no other feature or option changes. One must
first obtain a new keycode from Manufacturing for the new
M1 serial number.

1. Create the temporary directory 'd:\temp\serial_chg'
on the SCCS server.

2. Put the files : nortel.dll, ser_chg.exe, feature.R4,
nbcfg.dll and nbsopapi.dll in the temporary directory
'd:\temp\serial_chg'.
(Note : These files are unzipped from 'sccs0017.z'.)

3. Run the command d:\temp\serial_chg\ser_chg.exe

4. Enter the following keycode and serial number in the
fields provided and click the "OK" button.
(Note : Both the keycode and serial number are case sensitive.)

You should receive the message, "New Keycode and Serial Number
loaded successfully."

5. Confirm the change in keycode and M1 serial number by selecting
"Start -> Programs -> Symposium Call Center Server -> Feature Report"
Select the 'Features' tab.
The 'Keycode' and 'Serial Number' field should reflect the change.

6. Remove the directory and the files in the directory
'd:\temp\serial_chg'.

7. Reboot the server.

you would have to obtain the files from your support organisation