| BCM50 cd We have an Option 11C switch rel 24.24. On this switch is 1 PRI line. Everything's been running great for almost 3 years until yesterday when people started to complain about getting quick busy's when trying to make a call. When I look at the status of the PRI in LD 60 I see that I have 6 channels that are either "Busy" or "Idle" the other channels all have "FE MBSY". See Below: PRI* TRK LOOP 1 - ENBL FFMT/LCMT/YALMT: ESF/B8Z/FDL TRACKING SERVICE RESTORE: YES YEL ALM PROCESS: YES ALARM STATUS : NO ALARM CH 01 - IDLE DID 3VCE * CH 02 - IDLE DID 3VCE * CH 03 - BUSY DID 3VCE * CH 04 - IDLE DID 3VCE * CH 05 - BUSY DID 3VCE * CH 06 - FE MBSY DID 3VCE * CH 07 - FE MBSY DID 3VCE * CH 08 - FE MBSY DID 3VCE * CH 09 - FE MBSY DID 3VCE * CH 10 - FE MBSY DID 3VCE * CH 11 - FE MBSY DID 3VCE * CH 12 - FE MBSY DID 3VCE * CH 13 - FE MBSY DID 3VCE * CH 14 - FE MBSY DID 3VCE * CH 15 - FE MBSY DID 3VCE * CH 16 - FE MBSY DID 3VCE * CH 17 - FE MBSY DID 3VCE * CH 18 - FE MBSY DID 3VCE * CH 19 - FE MBSY DID 3VCE * CH 20 - FE MBSY DID 3VCE * CH 21 - FE MBSY DID 3VCE * CH 22 - FE MBSY DID 3VCE * CH 23 - FE MBSY DID 3VCE * CH 24 - DCH 3 Any ideas what may have happened? Thank You |