PBX Info :: Your Free PBX, PABX and Telephone Information Resource - View Single Post - NT1R20 Supervision Disconnect
View Single Post
Old 02-10-2005, 08:18 PM   #1 (permalink)
epsilon6
Junior Member

Activity Longevity
0/20 20/20
Today Posts
0/0 sssssss49
Location: Jacksonville, AR
Rep Power: 6epsilon6 is on a distinguished road
Send a message via ICQ to epsilon6 Send a message via AIM to epsilon6 Send a message via MSN to epsilon6 Send a message via Yahoo to epsilon6
Ok Guys, after reading some post on the board, I purchased two NT1R20 OPS Analog line cards for Hook Flash Disconnect for some emergency telephone in some elevators, however, I have not been able to get the line to work right. What am I doing wrong?

REQ: prt
TYPE: tnb
TN 4 0 9 0
DATE
PAGE
DES

DES 4000
TN 004 0 09 00
TYPE 500
CDEN DD
CUST 0
WRLS NO
DN 4000 0 MARP
CPND
NAME FAA Tower Elevator
XPLN 18
DISPLAY_FMT FIRST,LAST
AST NO
IAPG 0
HUNT
TGAR 8
LDN NO
NCOS 6
SGRP 0
RNPG 0
XLST
SCI 0
CLS CTD DTN FBD XFD WTA THFA FND HTD OPS
LPR XRD CWD SWD MWD RMMD SMWD LPD XHD SLKD CCSD TENA LND TVD
CFTD SFD C6D CNID CLBD AUTU
ICDD CDMD LLCN EHTD MCTD
GPUD DPUD CFXD ARHD OVDD AGTD CLTD LDTD ASCD
MBXD CPFA CPTA DDGA NAMA
MCRD LOL ABDD CFHD
USRD BNRD OCBD RTDD RBDD RBHD FAXD PGND FTTC
TEN 1
PLEV 02
AACS NO
FTR ISP 75
TIMP 600
BIMP 3CM2
DATE 10 FEB 2005


I do not want answer supervision, or battery reversal, just hook flash supervision. I made sure that the class of service of OPS was enable. Also enabled the ISP feature, as you can tell. Also made sure that the card density read DD. What am I missing?

Looking at a multi-meter, I never saw the voltage removed from the line. However, when it enabled feature OPS 1, I saw the battery reversal, but I need the voltage to be removed from the line.
epsilon6 is offline   sendpm.gif Reply With Quote