| We just connected our ethernet to our switch, however, we cannot seem to get remote notification in OTM to work. We setup the devices in Devices.TXT for Remote notifiation to read Meridian1 137.135.128.253 OTM 137.135.128.252 with the default Scripts.txt and other stuff. We also configured in our Opt 61C v25.30 open alarm to point to our OTM server - 137.135.128.252 LD 117 => SET OP 0 137.135.128.252 ^^^^ Flashback from my brain! I can go the Events in the Maintenance Windows and it will retrive the last 500 events FROM the swtich, but will not monitor the swtich live from Remote Notification. And yes, I did press the start button, but all it says is the script has started. I also did the following using a KIWI Syslog Daemon SNMP trap on another computer. LD 117 => SET OP 1 137.135.128.251 With no results there either. Am I doing something wrong, or is there something configured wrong in the switch? |