| It is a Dataset 1103 providing the interface. PMS emulator works perfectly, but the PBX rejects Room Restrict code changes from that too. It is Micros Fidelio Opera version 5.0. I went to this locations "sister" site, they have the same PBX and version and have the hard bound manuals onsite... The PMS section of the Optional Features manual make no mention of the RST function code on the PMS, well the LW34 manual I have does. I have pretty much come to the conclusion that this version of SX2000 software does not support that option and Micros has to find a way not to send those messages to the PBX. If you find out something else, by all means let me know. __________________ Telephony users cannot gain anything without first giving something in return. To obtain a useful feature, a feature of equal value must be lost. This is Telephony’s First Law of Equivalent Exchange. |