| R, This is from a nortel manual I came across, think it might help you. I'll see if I can find anymore useful info. to help in your knowledge quest. REQ: CHG TYPE: NET TYPE NET_DATA CUST 0 OPT AC2 FNP CLID YES < CLID Gate Opener SIZE INTL ENTRY 0 < CLID Table to be modified/created HNTN 972 < All Calls - NPA (Area Code) ESA_HLCL 362 < Emergency Calls - NXX (Local Exchange) ESA_INHN YES/NO < Emergency Calls - Include NPA on CLID ESA_APDN YES/NO < Emergency Calls - Include DN on CLID HLCL 362 < Normal Calls - NXX (Local Exchange) DIDN YES/NO < Normal Calls - Include DN on CLID HLOC 442 < UDP Calls - Home Location Code LSC 2 < CDP Call - Local Steering Code (if used) Figure 3: Command Line Interface CLID Table Creation in LD 15 __________________ Dogs rollover Phones hunt |