PBX Info :: Your Free PBX, PABX and Telephone Information Resource - View Single Post - T1 Maintenance Tests Flag
View Single Post
Old 10-19-2006, 09:00 AM   #1 (permalink)
rbohac
Junior Member

Activity Longevity
0/20 7/20
Today Posts
0/0 ssssssss2
Rep Power: 0rbohac is an unknown quantity at this point
Country:
T1 Maintenance Tests Flag

We have a robbed-bit T1 plugged into a Dialogic D/240 voice board. The T1 is currently configured at ESF/B8ZS however we can duplicate the following problem with it configured for D4/AMI as well.

We are initiating a service observe session on a T1 channel from the Dialogic card by dialing the service observer code and the then station. This works well. The problem is when agent puts a call on hold, there is some sort of a line error that causes the Avaya to hand up on the channel on the T1 when we have the "Maintenance Tests" option turned on for the trunk group. If we turn off "Maintenance Tests" we still see the error (via a T-Berd), however the service observing channel stays connected.

I'm at a loss as to why this would occur.. any thoughts?
rbohac is offline   sendpm.gif Reply With Quote