| Hi Erjamon There is a few commands that has to be activated to make a connection between BP250 and Hyperterminal (or any other terminal software). -activate command 6301 on all trunks -if you wish to log internal calls, activate 6201 -if you wish to log incoming calls, activate 6202 -deactivate 6203 -set 6204 to sent digits -under interface section, I/O ports, go to your com port (there are 3 RS232 COM ports on CPU, from 0-2 just bellow MOH input) - set following commands: -6006 - 5- CIL without line protocol -6007 - 1 -US ASCII -6009 - 9600 -6010 - 1- slave -6011 - unselected -6012 - CIL -go to Application I/O section -Commande 6401 - enter CPU port number (edited above) eg. 00000,00001 or 00002 -command 6403 - select output format - try with Call/Hotel CIL3Hotel -command 6402 - acivate Adjust your Hyperterminal connection settings to 9600,7E1,No flow control and try to connect. You will start to receive data from BP250. Be aware that buffer on Hyperterminal is limited to 500 records. After that oldest records will be overwritten. Also, if you acivate all above commands and disconnect PC from PBX, you can expect serious problems with system (can even restart) because data overflow. If you not planning to use CLI output, please disable commands 6301 on all trunks and disable COM port (deactivate 6402). Tell me if you need more informations. Good luck! Zoran Last edited by Zoran; 09-26-2006 at 06:48 PM. |